Digitala Vetenskapliga Arkivet

Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Qualifying CT for wrist arthroplasty: Extending techniques for total hip arthroplasty to total wrist arthroplasty
New York Medical College .
Karolinska.
Karolinska.
New York University.
Show others and affiliations
2005 (English)In: Medical Imaging 2005: Image Processing, Pt 1-3 / [ed] Fitzpatrick, JM; Reinhardt, JM, SPIE - The International Sooceity for Optical Engineeering , 2005, Vol. 5747, p. 1155-1164Conference paper, Published paper (Refereed)
Abstract [en]

The purpose of this study was to extend previous work to detect migration of total wrist arthroplasty non-invasively, and with greater accuracy. Two human cadaverous arms, each with a cemented total wrist implant, were used in this study. In one of the arms, I mm tantalum balls were implanted, six in the carpal bones and five in the radius. Five CT scans of each arm were acquired, changing the position of the arm each time to mimic different positions patients might take on repeated examinations. Registration of CT volume data sets was performed using an extensively validated, 3D semi-automatic volume fusion tool in which co-homologous point pairs (landmarks) are chosen on each volume to be registered. Three sets of ten cases each were obtained by placing landmarks on 1) bone only (using only arm one), 2) tantalum implants only, and 3) bone and tantalum implants (both using only arm two). The accuracy of the match was assessed visually in 2D and 3D, and numerically by calculating the distance difference between the actual position of the transformed landmarks and their ideal position (i.e., the reference landmark positions). All cases were matched visually within one width of cortical bone and numerically within one half CT voxel (0.32 mm, p = 0.05). This method matched only the bone/arm and not the prosthetic component per se, thus making it possible to detect prosthetic movement and wear. This method was clinically used for one patient with pain. Loosening of the carpal prosthetic component was accurately detected and this was confirmed at surgery.

Place, publisher, year, edition, pages
SPIE - The International Sooceity for Optical Engineeering , 2005. Vol. 5747, p. 1155-1164
Series
PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS (SPIE), ISSN 0277-786X
National Category
Radiology, Nuclear Medicine and Medical Imaging
Research subject
SRA - ICT
Identifiers
URN: urn:nbn:se:kth:diva-50111DOI: 10.1117/12.594582ISI: 000230109601049Scopus ID: 2-s2.0-23844548315ISBN: 0-8194-5721-3 (print)OAI: oai:DiVA.org:kth-50111DiVA, id: diva2:461036
Conference
Medical Imaging 2005 Conference. San Diego, CA. FEB 15-17, 2005
Note
QC 20111205Available from: 2011-12-01 Created: 2011-12-01 Last updated: 2022-06-24Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopushttp://link.aip.org/link/?PSI/5747/1155/1&Agg=doi

Search in DiVA

By author/editor
Maguire Jr., Gerald Q.
By organisation
Microelectronics and Information Technology, IMIT
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric score

doi
isbn
urn-nbn
Total: 453 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf