Ventilation Distribution Studies Comparing Technegas and "Gallgas" Using (GaCl3)-Ga-68 as the LabelVise andre og tillknytning
2011 (engelsk)Inngår i: Journal of Nuclear Medicine, ISSN 0161-5505, E-ISSN 1535-5667, Vol. 52, nr 2, s. 206-209Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]
Ventilation distribution can be assessed by SPECT with Technegas. This study was undertaken in piglets with different degrees of ventilation inhomogeneity to compare PET using Ga-68-labeled pseudogas or "Gallgas" with Technegas. Methods: Twelve piglets were studied in 3 groups: control, lobar obstruction, and diffuse airway obstruction. Two more piglets were assessed for lung volume (functional residual capacity). Results: In controls, SPECT and PET images showed an even distribution of radioactivity. With lobar obstruction, the absence of ventilation of the obstructed lobe was visible with both techniques. In diffuse airway obstruction, SPECT images showed an even distribution of radioactivity, and PET images showed more varied radioactivity over the lung. Conclusion: PET provides detailed ventilation distribution images and a better appreciation of ventilation heterogeneity. Gallgas with PET is a promising new diagnostic tool for the assessment of ventilation distribution.
sted, utgiver, år, opplag, sider
2011. Vol. 52, nr 2, s. 206-209
Emneord [en]
ventilation, Technegas, SPECT, Ga-68-pseudogas, PET
HSV kategori
Identifikatorer
URN: urn:nbn:se:uu:diva-146560DOI: 10.2967/jnumed.110.083881ISI: 000286594900011PubMedID: 21233191OAI: oai:DiVA.org:uu-146560DiVA, id: diva2:398445
2011-02-172011-02-172022-01-28bibliografisk kontrollert