A Monte Carlo-based model for simulation of digital chest tomosynthesis
Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Medicinsk radiofysik. Linköpings universitet, Hälsouniversitetet.
Royal Surrey County Hospital, Guildford.
Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Medicinsk radiofysik. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Kirurgi- och onkologicentrum, Radiofysikavdelningen.ORCID-id: 0000-0003-3352-8330
Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Medicinsk radiofysik. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Kirurgi- och onkologicentrum, Radiofysikavdelningen.ORCID-id: 0000-0003-0209-498X
Vise andre og tillknytning
2010 (engelsk)Inngår i: Radiation Protection Dosimetry, ISSN 0144-8420, E-ISSN 1742-3406, Vol. 139, nr 1-3, s. 159-163Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The aim of this work was to calculate synthetic digital chest tomosynthesis projections using a computer simulation model based on the Monte Carlo method. An anthropomorphic chest phantom was scanned in a computed tomography scanner, segmented and included in the computer model to allow for simulation of realistic high-resolution X-ray images. The input parameters to the model were adapted to correspond to the VolumeRAD chest tomosynthesis system from GE Healthcare. Sixty tomosynthesis projections were calculated with projection angles ranging from +15 to −15°. The images from primary photons were calculated using an analytical model of the anti-scatter grid and a pre-calculated detector response function. The contributions from scattered photons were calculated using an in-house Monte Carlo-based model employing a number of variance reduction techniques such as the collision density estimator. Tomographic section images were reconstructed by transferring the simulated projections into the VolumeRAD system. The reconstruction was performed for three types of images using: (i) noise-free primary projections, (ii) primary projections including contributions from scattered photons and (iii) projections as in (ii) with added correlated noise. The simulated section images were compared with corresponding section images from projections taken with the real, anthropomorphic phantom from which the digital voxel phantom was originally created. The present article describes a work in progress aiming towards developing a model intended for optimisation of chest tomosynthesis, allowing for simulation of both existing and future chest tomosynthesis systems.

sted, utgiver, år, opplag, sider
Oxford: Oxford University Press , 2010. Vol. 139, nr 1-3, s. 159-163
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-56402DOI: 10.1093/rpd/ncq079ISI: 000277738200027PubMedID: 20203125OAI: oai:DiVA.org:liu-56402DiVA, id: diva2:318790
Merknad
This is a pre-copy-editing, author-produced PDF of an article accepted for publication in Radiation Protection Dosimetry following peer review. The definitive publisher-authenticated version: Gustaf Ullman, David R. Dance, Michael Sandborg, Gudrun Alm Carlsson, Angelica Svalkvist and Magnus Båth, A MONTE CARLO-BASED MODEL FOR SIMULATION OF DIGITAL CHEST TOMOSYNTHESIS, 2010, Radiation Protection Dosimetry, (139), 1-3, 159-163. is available online at: http://dx.doi.org/10.1093/rpd/ncq079 Copyright: Oxford University Press http://www.oxfordjournals.org/ Tilgjengelig fra: 2010-05-10 Laget: 2010-05-10 Sist oppdatert: 2017-12-12

Open Access i DiVA

fulltekst(448 kB)1048 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 448 kBChecksum SHA-512
3bb982762b93e8c260621dc1057750cb3bfbc663add35a382ff00dae9eff4923f148482b605fb26a847f2c00892ba25798d958349a5e6fc822903bdb23489db7
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstPubMed

Søk i DiVA

Av forfatter/redaktør
Ullman, GustafSandborg, MichaelAlm Carlsson, Gudrun
Av organisasjonen
I samme tidsskrift
Radiation Protection Dosimetry

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 1048 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 224 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf