Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Estimation of the dose to the unborn child at diagnostic X-ray examinations based on data registrerad in RIS/PACS
Linköpings universitet, Institutionen för medicin och hälsa, Medicinsk radiofysik. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Centrum för kirurgi, ortopedi och cancervård, Radiofysikavdelningen US. (Landstinget i Östergötland)
Östergötlands Läns Landsting, Kirurgi- och onkologicentrum, Radiofysikavdelningen. Linköpings universitet, Institutionen för medicin och vård, Medicinsk radiofysik. Linköpings universitet, Hälsouniversitetet.
Linköpings universitet, Institutionen för medicin och hälsa, Medicinsk radiofysik. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Östergötlands Läns Landsting, Kirurgi- och onkologicentrum, Radiofysikavdelningen. Linköpings universitet, Hälsouniversitetet.ORCID-id: 0000-0003-3352-8330
Linköpings universitet, Institutionen för medicin och hälsa, Medicinsk radiofysik. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Centrum för kirurgi, ortopedi och cancervård, Radiofysikavdelningen US.
2007 (engelsk)Inngår i: European Radiology, ISSN 0938-7994, E-ISSN 1432-1084, Vol. 17, nr 1, s. 205-209Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The aim of this work was to determine mean absorbed doses to the unborn child in common conventional X-ray and computed tomography (CT) examinations and to find an approach for estimating foetal dose based on data registered in the Radiological Information System/Picture Archive and Communication System (RIS/PACS). The kerma-area product (KAP) and CT dose index (CTDIvol) in common examinations were registered using a human-shaped female dosimetry phantom. Foetal doses, Df, were measured using thermoluminescent dosimeters placed inside the phantom and compared with calculated values. Measured foetal doses were given in relation to the KAP and the CTDIvol values, respectively. Conversion factor Df/KAP varies between 0.01 and 3.8 mGy/Gycm2, depending on primary beam position, foetus age and beam quality (tube voltage and filtration). Conversion factors Df/CTDIvol are in the range 0.02 – 1.2 mGy/mGy, in which the foetus is outside or within the primary beam. We conclude that dose conversion factors based on KAP or CTDIvol values automatically generated by the RIS/PACS system can be used for rapid estimations of foetal dose for common examination techniques.

sted, utgiver, år, opplag, sider
2007. Vol. 17, nr 1, s. 205-209
Emneord [en]
Pregnancy - Radiation - Foetal dose - Radiological protection - Patient doses
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-21427DOI: 10.1007/s00330-006-0286-2ISI: 000243396700024OAI: oai:DiVA.org:liu-21427DiVA, id: diva2:241275
Tilgjengelig fra: 2009-10-01 Laget: 2009-10-01 Sist oppdatert: 2017-12-13

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Søk i DiVA

Av forfatter/redaktør
Helmrot, EbbaPettersson, HåkanSandborg, MichaelNilsson Althen, Jonas
Av organisasjonen
I samme tidsskrift
European Radiology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 170 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf