Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Energiförbrukning för putsade, odränerade träregelväggar i fuktigt respektive torrt tillstånd
Örebro universitet, Akademin för naturvetenskap och teknik.
2009 (svensk)Independent thesis Basic level (professional degree), 10 poäng / 15 hpOppgave
Abstract [en]

In recent years, moisture damages have been noticed in rendered, undrained stud walls. The design is built on the principle one-stage tightening which means that there is no air gap in the construction. The damages have occurred when water has permeated through the rendering in leaking connections and fittings for windows, doors, canopies, balconies, terraces and awnings. Behind the plaster carrier, which consists of either polystyrene or rigid mineral wool, plasterboard has often been used as a wind protection barrier. In many cases the wind protection barrier and the underlying wooden studs have been exposed to mould and in some cases even rot. It has been shown that damp in the structure is difficult to dry out.

The aim of the thesis has been to examine how the energy consumption is affected when this type of construction is damp, partly because energy is required to dry up damp, partly because the insulation ability for a material decreases when it is affected by moisture.

Previous research and relevant literature has been used in this thesis, to provide: A comprehensive picture of the problem, an explanation for the calculations used and an understanding of the conclusions drawn.

The energy consumption has been calculated for 1 m2 wall area on two types of wall designs. The calculations have been performed in both dry and damp condition. To calculate the energy consumption in damp condition, three different types of calculation models have been used in three different ways. Since no measurements have been made, the calculations are to some extent based on assumed values.

The amount of damp that have entered the structure has, according to the calculation models used, been shown to produce small differences in energy consumption compared to the dry structure. The main problem for these types of walls seems instead to be the growth of microorganisms. Nevertheless, the microorganisms seem not to have affected the indoor environment in any significant manner.

sted, utgiver, år, opplag, sider
2009. , s. 46
Emneord [sv]
Puts, Fasader, Odränerade, Energiförbrukning, Träregelväggar
HSV kategori
Identifikatorer
URN: urn:nbn:se:oru:diva-7861ISRN: ORU-NAT/BYG-GY-2009/0001--SEOAI: oai:DiVA.org:oru-7861DiVA, id: diva2:234585
Presentation
(engelsk)
Uppsök
Technology
Veileder
Examiner
Tilgjengelig fra: 2009-09-14 Laget: 2009-09-09 Sist oppdatert: 2017-10-18bibliografisk kontrollert

Open Access i DiVA

fulltekst(2090 kB)899 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 2090 kBChecksum SHA-512
db619d32ad361aa3aee1932492138b1e24f7cef2ad5381f55b2fe284cd6647d4ad44035122e1f8de5f389650b27f09370c706624b09c92a5e05ca1e207c1c0a6
Type fulltextMimetype application/pdf

Søk i DiVA

Av forfatter/redaktør
Arvidsson, Erik
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 899 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 399 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf