Comparison of quantitative [11C]PE2I brain PET studies between an integrated PET/MR and a stand-alone PET system
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Radiologi. Uppsala Univ, Uppsala Univ Hosp, Dept Surg Sci, PET Ctr, S-75185 Uppsala, Sweden..ORCID-id: 0000-0002-1498-1327
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Radiologi. Uppsala Univ Hosp, Med Imaging Ctr, Uppsala, Sweden..
Collect Minds Radiol AB, Taby, Sweden..
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för medicinska vetenskaper, Neurologi. Uppsala Univ Hosp, Dept Neurol, Uppsala, Sweden..ORCID-id: 0000-0001-9776-7715
Visa övriga samt affilieringar
2024 (Engelska)Ingår i: Physica medica (Testo stampato), ISSN 1120-1797, E-ISSN 1724-191X, Vol. 117, artikel-id 103185Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

PET/MR systems demanded great efforts for accurate attenuation correction (AC) but differences in technology, geometry and hardware attenuation may also affect quantitative results. Dedicated PET systems using transmission-based AC are regarded as the gold standard for quantitative brain PET. The study aim was to investigate the agreement between quantitative PET outcomes from a PET/MR scanner against a stand-alone PET system.Nine patients with Parkinsonism underwent two 80-min dynamic PET scans with the dopamine transporter ligand [11C]PE2I. Images were reconstructed with resolution-matched settings using 68Ge-transmission (standalone PET), and zero-echo-time MR (PET/MR) scans for AC. Non-displaceable binding potential (BPND) and relative delivery (R1) were evaluated using volumes of interest and voxel-wise analysis.Correlations between systems were high (r >= 0.85) for both quantitative outcome parameters in all brain regions. Striatal BPND was significantly lower on PET/MR than on stand-alone PET (-7%). R1 was significantly overestimated in posterior cortical regions (9%) and underestimated in striatal (-9%) and limbic areas (-6%). The voxel-wise evaluation revealed that the MR-safe headphones caused a negative bias in both parametric BPND and R1 images. Additionally, a significant positive bias of R1 was found in the auditory cortex, most likely due to the acoustic background noise during MR imaging. The relative bias of the quantitative [11C]PE2I PET data acquired from a SIGNA PET/MR system was in the same order as the expected test-retest reproducibility of [11C]PE2I BPND and R1, compared to a stand-alone ECAT PET scanner. MR headphones and background noise are potential sources of error in functional PET/MR studies.

Ort, förlag, år, upplaga, sidor
Elsevier, 2024. Vol. 117, artikel-id 103185
Nyckelord [en]
Positron emission tomography, Dopamine transporter, Cerebral blood flow, PET quantification
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:uu:diva-520362DOI: 10.1016/j.ejmp.2023.103185ISI: 001129803800001PubMedID: 38042064OAI: oai:DiVA.org:uu-520362DiVA, id: diva2:1827846
Forskningsfinansiär
Vetenskapsrådet, 2011-6269Vetenskapsrådet, 2016-01040Hjärt-Lungfonden, 20170492Tillgänglig från: 2024-01-15 Skapad: 2024-01-15 Senast uppdaterad: 2024-01-15Bibliografiskt granskad

Open Access i DiVA

fulltext(3601 kB)156 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 3601 kBChecksumma SHA-512
81b43c268f7dc0fa335fc76c1c88d63ce0772e329626ab6ec22fe5bdcf54d7dc3d49fe72d8c2a9f14761c4b44ab2fa2f59edf05ec32170b452da9a083bcbbfb9
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMed

Sök vidare i DiVA

Av författaren/redaktören
Sousa, Joao M.Appel, LieuweNyholm, DagAhlström, HåkanLubberink, Mark
Av organisationen
RadiologiNeurologi
I samma tidskrift
Physica medica (Testo stampato)
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 157 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 190 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf