Digitala Vetenskapliga Arkivet

Planned maintenance
A system upgrade is planned for 10/12-2024, at 12:00-13:00. During this time DiVA will be unavailable.
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Digital goniometer: Ett mätverktyg för att effektivisera rehabilitering efter böjsenskada
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH), Biomedical Engineering and Health Systems.
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH), Biomedical Engineering and Health Systems.
2023 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Digital Goniometer : A Measurement Tool to Streamline Rehabilitation After Flexor Tendon Injury (English)
Abstract [sv]

Mellan år 2020 och år 2021 registrerades 381 operationer av böjsenskador i Sverige. Rehabiliteringsprocessen efter en böjsenskada är lång och kräver kontinuerlig uppföljning. Uppföljningen sker genom mätningar av böj- och sträckförmågan i de fingrar som patienten opererat. Mätningarna utförs i nuläget manuellt med goniometer, där vinklarna i fingrarnas leder mäts, en gång per vecka på en handkirurgisk mottagning. Handkirurgiska kliniken på Södersjukhuset i Stockholm efterfrågade ett digitalt mätverktyg som skulle göra det möjligt för patienten att på ett tillförlitligt sätt mäta vinklarna hemma i stället för på kliniken. Målet med projektet var således att skapa ett mätverktyg som mäter vinklarna med ett mätfel på högst 5 grader. Ett mätverktyg utvecklades som utför mätning av vinklar med hjälp av en bild användaren tagit. Mätverktyget är kompatibelt med Androidenheter och kan implementeras i en redan existerande Androidapplikation. Tester visade att mätverktyget har ett mätfel med ett medelvärde på 5 grader eller lägre för proximala interfalangealleden och distala interfalangealleden. Vidare var medelfelet 7,3 grader respektive 6,4 grader för metakarpofalangealleden vid böjt respektive sträckt finger, samt 10 grader för totalt aktivt rörelseomfång (total active motion).

Abstract [en]

Between 2020 and 2021, 381 operations for flexor tendon injuries were registered in Sweden. The rehabilitation following surgery is long and requires continuous monitoring. Presently the monitoring is done through manual measurements of the patients flexing and extending capability of the fingers affected. The measurement is performed at a hand surgery department with a handheld goniometer, initially once a week. The hand surgery department at Södersjukhuset in Stockholm requested a digital tool that allows the patient to reliably measure the angles of the fingers bending and stretching capability at home instead of at the clinic. The objective of the project was therefore to create a measurement tool that measures these angles with a maximum error of 5 degrees. A measurement tool was developed where the measurement of angles takes place from an image taken by the user. The measurement tool is compatible with Android devices and can be implemented in an existing Android application. Tests showed that the measurement tool has a mean measurement error of 5 degrees or less for the proximal interphalangeal joint and the distal interphalangeal joint. In addition, the mean error was 7.3 degrees and 6.4 degrees for the metacarpophalangeal joint, bent and stretched respectively, and 10 degrees for total active motion.

Place, publisher, year, edition, pages
2023. , p. 78
Series
TRITA-CBH-GRU ; 2023:123
Keywords [en]
Angle measurement, Flexor tendon injury, Rehabilitation, TAM, Mobile application, Digital tool
Keywords [sv]
Vinkelmätning, Böjsenskada, Rehabilitering, TAM, Mobilapplikation, Digitalt verktyg
National Category
Other Medical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-330387OAI: oai:DiVA.org:kth-330387DiVA, id: diva2:1777730
External cooperation
Handkirurgiska kliniken, Södersjukhuset, 118 83 Stockholm
Subject / course
Medical Engineering
Educational program
Master of Science in Engineering - Medical Engineering
Supervisors
Examiners
Available from: 2023-07-04 Created: 2023-06-29 Last updated: 2023-07-04Bibliographically approved

Open Access in DiVA

Digital goniometer: Ett mätverktyg för att effektivisera rehabilitering efter böjsenskada(4606 kB)190 downloads
File information
File name FULLTEXT01.pdfFile size 4606 kBChecksum SHA-512
55d9308bf4f4509e9a9a6aa2311f09fa5d2cb684164a09196216372bbe02a12ccc87b280a353755ae48f25237153da7245d54e9e4d88c05df4dcbbfd5db0323f
Type fulltextMimetype application/pdf
Mätverktygets kod(519 kB)57 downloads
File information
File name FULLTEXT02.pdfFile size 519 kBChecksum SHA-512
fd2aaaa7d85ec8e299818371d495a894fba11be7ed7488a74c9049e84c65934e1f5afd3f515f5abd01664442a44a62950a8be5cf0542d4ece53f7b3227733a8c
Type attachmentMimetype application/pdf
Filmer som används i mätverktyget(65487 kB)20 downloads
File information
File name MOVIE01.zipFile size 65487 kBChecksum SHA-512
2345c41e35dc60ebedca2d0ea4cc803246ac0f09a9708b7bbb87f2a3df0321d2832a549dfc6ef9d52d46e1e87b863a93a1bc56bd207a5f50f60d8e11bc054d72
Type movieMimetype application/zip

By organisation
Biomedical Engineering and Health Systems
Other Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 247 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 403 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf