Digitala Vetenskapliga Arkivet

Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Test–retest reliability of splenic volume assessment by ultrasonography
Mittuniversitetet, Fakulteten för humanvetenskap, Institutionen för hälsovetenskaper (HOV).ORCID-id: 0000-0003-1957-1527
Mittuniversitetet, Fakulteten för humanvetenskap, Institutionen för hälsovetenskaper (HOV).ORCID-id: 0000-0002-9787-6660
Mittuniversitetet, Fakulteten för humanvetenskap, Institutionen för hälsovetenskaper (HOV). (Swedish Winter Sports Research Centre)ORCID-id: 0000-0001-5477-9265
2022 (Engelska)Ingår i: Scientific Reports, E-ISSN 2045-2322, Vol. 12, nr 1, artikel-id 18976Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

While MRI and CT are the gold standards for assessments of splenic size in clinical settings, ultrasonography is particularly suited due to its portability, cost efficiency and easy utilization. However, ultrasonography is associated with subjective assessment, potentially resulting in increased variation. We used a test–retest design aiming to determine the reliability of splenic measurements assessed by ultrasonography during apnea. In addition, we compared reliability between different equations for volume calculations: Koga, Prolate ellipsoid and Pilström. Twelve healthy participants (6 women) performed two tests separated by 15 min, comprising a maximal voluntary apnea in a seated position. Splenic dimensions were measured via ultrasonography for 5 min before and immediately following apnea. Resting splenic volume displayed high test–retest reliability between tests (Pilström: 157 ± 39 mL vs 156 ± 34 mL, p = .651, ICC = .970, p < .001, CV = 2.98 ± 0.1%; Prolate ellipsoid: 154 ± 37 mL vs 144 ± 43 mL, p = .122, ICC = .942, p < .001, CV = 5.47 ± 0.3%; Koga: 142 ± 37 mL vs 140 ± 59 mL, p = .845, ICC = .859, p < .001, CV = 9.72 ± 1.4%). Apnea-induced volumes displayed similar reliability (127 ± 29 mL vs 129 ± 28 mL, p = .359, ICC = .967, p < .001, CV = 3.14 ± 3.1%). Reliability was also high between equations (Pilström vs Prolate ellipsoid: ICC = .818, p < .001, CV = 7.33 ± 0.3%, bias =  − 3.1 mL, LoA =  − 46.9 to 40.7 mL; Pilström vs Koga: ICC = .618, p < .01, CV = 11.83 ± 1.1%, bias =  − 14.8 mL, LoA =  − 76.9 to 47.3 mL). We conclude that splenic ultrasonographic measurements have practical applications during laboratory and field-based research as a reliable method detecting splenic volume change consistently between repeated tests. The Pilström equation displayed similar reliability compared to the prolate ellipsoid formula and slightly higher compared to the Koga formula and may be particularly useful to account for individual differences in splenic dimensions.

Ort, förlag, år, upplaga, sidor
Nature Publishing Group, 2022. Vol. 12, nr 1, artikel-id 18976
Nationell ämneskategori
Medicinska och farmaceutiska grundvetenskaper Hälsovetenskaper Fysiologi och anatomi
Identifikatorer
URN: urn:nbn:se:miun:diva-46411DOI: 10.1038/s41598-022-23384-6ISI: 000880437400029PubMedID: 36347952Scopus ID: 2-s2.0-85141377085OAI: oai:DiVA.org:miun-46411DiVA, id: diva2:1709613
Forskningsfinansiär
MittuniversitetetTillgänglig från: 2022-11-09 Skapad: 2022-11-09 Senast uppdaterad: 2025-02-10Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Sök vidare i DiVA

Av författaren/redaktören
Holmström, PontusPernett, FrankSchagatay, Erika
Av organisationen
Institutionen för hälsovetenskaper (HOV)
I samma tidskrift
Scientific Reports
Medicinska och farmaceutiska grundvetenskaperHälsovetenskaperFysiologi och anatomi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 522 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf