Accuracy of iodine quantification using dual-energy computed tomography with focus on low concentrations.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Radiologi.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Radiologi.
Vise andre og tillknytning
2022 (engelsk)Inngår i: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 63, nr 5, s. 623-631, artikkel-id 2841851211009462Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

BACKGROUND: Iodine quantification using dual-energy computed tomography (DECT) is helpful in characterizing, and follow-up after treatment of tumors. Some malignant masses, for instance papillary renal cell carcinomas (p-RCC), are hard to differentiate from benign lesions because of very low contrast enhancement. In these cases, iodine concentrations might be very low, and it is therefore important that iodine quantification is reliable even at low concentrations if this technique is used.

PURPOSE: To examine the accuracy of iodine quantification and to determine whether it is also accurate for low iodine concentrations.

MATERIAL AND METHODS: Twenty-six syringes with different iodine concentrations (0-30 mg I/mL) were scanned in a phantom model using a DECT scanner with two different kilovoltage and image reconstruction settings. Iodine concentrations were measured and compared to known concentration. Absolute and relative errors were calculated.

RESULTS: For concentrations of 1 mg I/mL or higher, there was an excellent correlation between true and measured iodine concentrations for all settings (R = 0.999-1.000; P < 0.001). For concentrations <1.0 mg I/mL, the relative error was greater. Absolute and relative errors were smaller using tube voltages of 80/Sn140 kV than 100/Sn140 kV (P < 0.01). Reconstructions using a 3.0-mm slice thickness had less variance between repeated acquisitions versus 0.6 mm (P < 0.001).

CONCLUSION: Iodine quantification using DECT was in general very accurate, but for concentrations < 1.0 mg I/mL the technique was less reliable. Using a tube voltage with larger spectral separation was more accurate and the result was more reproducible using thicker image reconstructions.

sted, utgiver, år, opplag, sider
SAGE Publications Sage Publications, 2022. Vol. 63, nr 5, s. 623-631, artikkel-id 2841851211009462
Emneord [en]
Iodine quantification, dual-energy computed tomography, phantom study, tumor enhancement
HSV kategori
Identifikatorer
URN: urn:nbn:se:uu:diva-441137DOI: 10.1177/02841851211009462ISI: 000680627300001PubMedID: 33887965OAI: oai:DiVA.org:uu-441137DiVA, id: diva2:1547319
Tilgjengelig fra: 2021-04-26 Laget: 2021-04-26 Sist oppdatert: 2024-12-03bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Søk i DiVA

Av forfatter/redaktør
Ahnfelt, AndersDahlman, PärMagnusson, Anders
Av organisasjonen
I samme tidsskrift
Acta Radiologica

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 71 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf