GMP production of [Ga-68]Ga-BOT5035 for imaging of liver fibrosis in microdosing phase 0 study
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Farmaceutiska fakulteten, Institutionen för läkemedelskemi.ORCID-id: 0000-0002-3732-8857
Uppsala Univ Hosp, PET Ctr, Ctr Med Imaging, SE-75185 Uppsala, Sweden..
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Farmaceutiska fakulteten, Institutionen för läkemedelskemi.
BiOrion Technol BV, Groningen, Netherlands..
Visa övriga samt affilieringar
2020 (Engelska)Ingår i: Nuclear Medicine and Biology, ISSN 0969-8051, E-ISSN 1872-9614, Vol. 88-89, s. 73-85Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Introduction: Early detection of liver fibrosis and monitoring response to treatment crucial for the management of patients are currently not feasible in clinical practice. Platelet derived growth factor receptor beta (PDGER-beta) expression is regarded as a potential biomarker to determine the stages of fibrotic diseases including liver fibrosis. [Ga-68]Ga-BOT5035 comprising a bicyclic peptide was developed for specific targeting of ppGrR-beta overexpressed in pathological fibrosis. The realization of microdosing phase 0 study using [Ga-68]Ga-BOT5035 positron emission tomography required automated good manufacturing practice (GMP) compliant production of [Ga-68]Ga-BOT5035 presented herein. Moreover, the investigation of radiation dosimetry was conducted to ensure possibility of multiple annual examinations for disease monitoring in clinical setup.

Methods: The active pharmaceutical ingredient starting material BOT5035 (GMP grade) was provided by BiOrion Technologies BV. The Ga-68-labelling process was developed and automated using synthesis platform (ModularLab PharmTrace, Eckert & Ziegler), disposable cassettes for Ga-68-labelling, and pharmaceutical grade Ge-68/Ga-68 generator (GalliaPharm (R)) purchased from Eckert & Ziegler. Radiolysis sensitive BOT5035 required development and systematic optimization of the labelling synthesis parameters such as time, temperature, precursor concentration, radical scavenger, buffer concentration and pH. The validation process was conducted with regard to the product quality and quantity, as well as production reproducibility. Human organ equivalent doses and total body effective doses were calculated using Organ Level Internal Dose Assessment Code software (OLINDA/EXM 1.1), based on ex vivo organ distribution in Sprague-Dawley rats.

Results: The GMP compliant automated production of [Ga-68]Ga-BOT5035 with on-line documentation demonstrated high reproducibility. The time for the labelling synthesis and quality control was approximately 60 min. The non-decay corrected radiochemical yield and radiochemical purity of the radiopharmaceutical were 43.7 +/- 7.6% (n = 3, process validation) and 97.7 +/- 0.4% (n = 3, process validation), respectively. Predefined acceptance criteria were met for the sterility, endotoxins level, radionuclidic purity and residual solvent content. The stability at ambient temperature was controlled for 120 min with approved results. Ex vivo organ distribution data revealed fast blood clearance and washout from most of the organs. The dose-limiting organs were kidney and bone marrow. The total effective dose as limiting parameter would allow for up to 3-4 PET scans per annum.

Conclusion: The fully automated and GMP compliant production of [Ga-68]Ga-BOT5035 was developed and thoroughly validated. The radiopharmaceutical was approved by Swedish Medicinal Products Agency and the Ethical Review Authority for the Phase 0 clinical study of the quantitative imaging of liver fibrosis. Human dosimetry calculations extrapolated from animal experiment indicated possibility of 3-4 PET examinations per year.

Ort, förlag, år, upplaga, sidor
ELSEVIER SCIENCE INC , 2020. Vol. 88-89, s. 73-85
Nyckelord [en]
Liver fibrosis, Plateled derived growth factor receptor beta, GMP, Gallium-68, Automation, Radiopharmaceuticals
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:uu:diva-425245DOI: 10.1016/j.nucmedbio.2020.07.009ISI: 000582305600009PubMedID: 32805638OAI: oai:DiVA.org:uu-425245DiVA, id: diva2:1501130
Forskningsfinansiär
Knut och Alice Wallenbergs StiftelseVinnova, 2017-03465Tillgänglig från: 2020-11-16 Skapad: 2020-11-16 Senast uppdaterad: 2020-11-16Bibliografiskt granskad

Open Access i DiVA

fulltext(2984 kB)395 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 2984 kBChecksumma SHA-512
39550af5306bf409a0b19cdf7a9d5a9473692775e815485e22ee1350bbf9aab11b43c650e87726a48a5799dc038156f9f4bd835dae6b0a13c90b54399c6e71b7
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMed

Sök vidare i DiVA

Av författaren/redaktören
Velikyan, IrinaEstrada, SergioAntoni, Gunnar
Av organisationen
Institutionen för läkemedelskemi
I samma tidskrift
Nuclear Medicine and Biology
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 396 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 142 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf