ATES SYSTEM MONITORING PROJECT, FIRST MEASUREMENT AND PERFORMANCE EVALUATION: CASE STUDY IN SWEDEN
KTH, Skolan för industriell teknik och management (ITM), Energiteknik, Tillämpad termodynamik och kylteknik. (GeoEnergy)ORCID-id: 0000-0002-6742-2684
KTH, Skolan för industriell teknik och management (ITM), Energiteknik, Tillämpad termodynamik och kylteknik. (GeoEnergy)ORCID-id: 0000-0002-3490-1777
2018 (Engelska)Ingår i: Proceedings of the IGSHPA Research Track 2018, 2018Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Performance of Aquifer Thermal Energy Storage (ATES) systems for seasonal thermal storage depends on the temperature of the extracted/injected groundwater, water pumping rates and the hydrogeological conditions of the aquifer. ATES systems are therefore often designed to maintain a temperature difference possible between the warm side and cold side of the aquifer, without risking hydraulic and thermal intrusion between them or thermal leakage to surrounding area, i.e. maximize hydraulic and thermal recovery. Monitoring the operation of pumping and observation wells is crucial for the validation of ATES groundwater models utilized for their design, and measured data provides valuable information for researchers and practitioners working in the field. After months of planning and installation work, selected measurements recorded in an ATES monitoring project in Sweden during the first three seasons of operation are reported in this paper. The ATES system is located in Solna, in Stockholm esker, and it is used to heat and cool two commercial buildings with a total area of around 30,000 m 2 . The ATES consists of 3 warm and 2 cold pumping wells that are able to pump up to 50 liters per second. The monitoring system consists of temperature sensors and flow meters placed at the pumping wells, a distributed temperature-sensing rig employing fiber optic cables as linear sensor and measuring temperature every 0.25 m along the depth of all pumping and several observation wells, yielding temporal and spatial variation data of the temperature in the aquifer. The heat injection and extraction to and from the ground is measured using power meters at the main line connecting the pumping wells to the system. The total heat and cold extracted from the aquifer during the first heating and cooling season is 190MWh and 237MWh, respectively. A total of 143 MWh of heat were extracted during the second heating season. The hydraulic and thermal recovery values of the first year of operation was 1.37 and 0.33, respectively, indicating that more storage volume (50500m3 ) was recovered during the cooling season than injected (36900m3 ) in the previous heating season. The DTS data showed traces of the thermal front from the warm storage reaching the cold one. Only 33% of the thermal energy was recovered. These losses are likely due to ambient groundwater flow as well as conduction losses at the boundaries of the storage volume. Additionally, the net energy balance over the first year corresponds to 0.12 which indicates a total net heating of the ATES over the first year. It is recommended to increase the storage volume and achieve more hydraulic and thermal balance in the ATES system. This can enhance the thermal recovery and overall performance. Continuous monitoring of the ATES is and will be ongoing for at least 3 more years. The work presented in this paper is an initial evaluation of the system aiming to optimize the ATES performance.

Ort, förlag, år, upplaga, sidor
2018.
Nyckelord [en]
Heat Pump, Heating, Free Cooling, DTS, Thermal energy storage, Aquifer, ATES, monitoring
Nationell ämneskategori
Energiteknik
Forskningsämne
Energiteknik
Identifikatorer
URN: urn:nbn:se:kth:diva-243836DOI: 10.22488/okstate.18.000002OAI: oai:DiVA.org:kth-243836DiVA, id: diva2:1286401
Konferens
IGSHPA Research Track 2018
Forskningsfinansiär
Energimyndigheten, Projektnummer 40942-1 Effsys Expand P22
Anmärkning

QC 20190211

Tillgänglig från: 2019-02-06 Skapad: 2019-02-06 Senast uppdaterad: 2019-02-11Bibliografiskt granskad

Open Access i DiVA

fulltext(1583 kB)126 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 1583 kBChecksumma SHA-512
d85ac012adf65f8a8a7e9b7043d12673f12320cde8365ed86316396000a90f356a65cbeb9fc3e63a8dffc0e2205a0ee7c61f443a205a5e806e16510fa699954c
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltext

Sök vidare i DiVA

Av författaren/redaktören
Abuasbeh, MohammadAcuña, José
Av organisationen
Tillämpad termodynamik och kylteknik
Energiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 126 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 806 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf