Reliability and agreement of the IsoKai isokinetic lift test - A test used for admission to the Swedish Armed Forces
Umeå universitet, Medicinska fakulteten, Institutionen för samhällsmedicin och rehabilitering. Department of Neurobiology, Care Sciences and Society, Division of Physiotherapy, Karolinska Institutet, Stockholm, Sweden.
Visa övriga samt affilieringar
2018 (Engelska)Ingår i: PLoS ONE, ISSN 1932-6203, E-ISSN 1932-6203, Vol. 13, nr 12, artikel-id e0209419Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

This study was performed to evaluate the reliability and agreement of the IsoKai isokinetic lift test as it is currently administered in admission to the Swedish Armed Forces. The study included an intrarater (n = 534) and interrater reliability sample (n = 137), of Swedish male conscripts who performed the test on two test occasions about two hours apart. Two-to-four lifts were performed at each occasion, and the highest mean (IsoKai(MF)) and peak force (IsoKai(PF)) produced (N) were used for evaluation. All intraclass coefficients showed excellent reliability. The interrater analyses resulted in intraclass coefficients of 0.942 (95% CI; 0.920-0.959) and 0.858 (95% CI; 0.806-0.896) for the IsoKai(MF) and IsoKai(PF), respectively, while the corresponding coefficients for the intrarater analyses were 0.935 (95% CI; 0.923-0.946) and 0.865 (95% CI; 0.842-0.886). Agreement, the capability of a test to detect changes, was assessed by the standard error of measurement (SEM/SEM%) and the smallest real difference (SRD/SRD%). These estimate indicated that it is possible to achieve measurements relevant to use in real practice with the IsoKai isokinetic lift test. Bland and Altman analyses revealed no systematic errors in either sample. Based on these findings, the IsoKai isokinetic lift test is suggested to be a highly reliable test for maximal dynamic muscular strength. The test could be of use in selection procedures in order to accurately evaluate maximal dynamic muscular strength, and for evaluating longitudinal changes in strength.

Ort, förlag, år, upplaga, sidor
Public Library Science , 2018. Vol. 13, nr 12, artikel-id e0209419
Nationell ämneskategori
Övrig annan medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:umu:diva-155098DOI: 10.1371/journal.pone.0209419ISI: 000453779300090PubMedID: 30566536OAI: oai:DiVA.org:umu-155098DiVA, id: diva2:1277356
Tillgänglig från: 2019-01-10 Skapad: 2019-01-10 Senast uppdaterad: 2019-01-10Bibliografiskt granskad

Open Access i DiVA

fulltext(1655 kB)91 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 1655 kBChecksumma SHA-512
74bb7a600ec638b93fc1a18e49f7533c0518ce54c21e26fdab22e644d4f545f041573788f7263de81bf4541ab1fce1a874b820e1678fb02fb8d44ac524414d12
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMed

Sök vidare i DiVA

Av författaren/redaktören
Tegern, Matthias
Av organisationen
Institutionen för samhällsmedicin och rehabilitering
I samma tidskrift
PLoS ONE
Övrig annan medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 91 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 155 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf