Test-retest reliability of new and conventional echocardiographic parameters of left ventricular systolic function
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Medicinska och farmaceutiska vetenskapsområdet, centrumbildningar mm, UCR-Uppsala Clinical Research Center. Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Medical Sciences, Cardiology. Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Medical Sciences, Clinical Physiology.ORCID iD: 0000-0002-8290-557X
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Medicinska och farmaceutiska vetenskapsområdet, centrumbildningar mm, UCR-Uppsala Clinical Research Center. Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Public Health and Caring Sciences, Geriatrics.
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Medical Sciences, Cardiology-Arrhythmia.
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Medical Sciences, Clinical Physiology. Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Medical Sciences, Cardiology.
2019 (English)In: Clinical Research in Cardiology, ISSN 1861-0684, E-ISSN 1861-0692, Vol. 108, no 4, p. 355-365Article in journal (Refereed) Published
Abstract [en]

Background: Reliability of left ventricular function measurements depends on actual biological conditions, repeated registrations and their analyses.

Objective: To investigate test–retest reliability of speckle-tracking-derived strain measurements and its determinants compared to the conventional parameters, such as ejection fraction (EF), LV volumes and mitral annular plane systolic excursion (MAPSE).

Methods: In 30 patients with a wide range of left ventricular function (mean EF 46.4 ± 16.4%, range 14–73%), standard echo views were acquired independently in a blinded fashion by two different echocardiographers in immediate sequence and analyzed off-line by two independent readers, creating 4 data sets per patient. Test–retest reliability of studied parameters was calculated using the smallest detectable change (SDC) and a total, inter-acquisition and inter-reader intra-class correlation coefficient (ICC).

Results: The smallest detectable change normalized to the mean absolute value of the measured parameter (SDCrel) was lowest for MAPSE (10.7%). SDCrel for EF was similar to GLS (14.2 and 14.7%, respectively), while SDCrel for CS was much higher (35.6%). The intra-class correlation coefficient was excellent (> 0.9) for all measures of the left ventricular function. Intra-patient inter-acquisition reliability (ICCacq) was significantly better than inter-reader reliability (ICCread) (0.984 vs. 0.950, p = 0.03) only for EF, while no significant difference was observed for any other LV function parameter. Mean intra-subject standard deviations were significantly correlated to the mean values for CS and LV volumes, but not for the other studied parameters.

Conclusions: In a test–retest setting, both with normal and impaired left ventricular function, the smallest relative detectable change of EF, GLS and MAPSE was similar (11–15%), but was much higher for CS (35%). Surprisingly, reliability of GLS was not superior to that of EF. Acquisition and reader to a similar extent influenced the reliability of measurements of all left ventricular function measures except for ejection fraction, where the reliability was more dependent on the reader than on the acquisition.

Place, publisher, year, edition, pages
2019. Vol. 108, no 4, p. 355-365
Keywords [en]
Ejection fraction, Global longitudinal strain, Left ventricular function, Mitral annulus plane systolic excursion, Test–retest reliability
National Category
Cardiac and Cardiovascular Systems
Research subject
Cardiology
Identifiers
URN: urn:nbn:se:uu:diva-368888DOI: 10.1007/s00392-018-1363-7ISI: 000462198300002PubMedID: 30368567OAI: oai:DiVA.org:uu-368888DiVA, id: diva2:1269259
Available from: 2018-12-10 Created: 2018-12-10 Last updated: 2019-04-17Bibliographically approved

Open Access in DiVA

fulltext(3523 kB)32 downloads
File information
File name FULLTEXT02.pdfFile size 3523 kBChecksum SHA-512
5c198d86cfecc221989e7845740800d5b32e973166bcdd8c1859a4b1db4271964c2ff06edd9771d0baaf993b9ff16fc2f9aef629036dd36e6f5423e1366c2684
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Baron, TomaszBerglund, LarsHedin, Eva-MariaFlachskampf, Frank
By organisation
UCR-Uppsala Clinical Research CenterCardiologyClinical PhysiologyGeriatricsCardiology-Arrhythmia
In the same journal
Clinical Research in Cardiology
Cardiac and Cardiovascular Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 35 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 212 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf