Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Comparison of ppb-level gas measurements with a metal-oxide semiconductor gas sensor in two independent laboratories
Linköpings universitet, Institutionen för fysik, kemi och biologi, Sensor- och aktuatorsystem. Linköpings universitet, Tekniska fakulteten. Saarland Univ, Germany.
Saarland Univ, Germany.
Bundesanstalt Mat Forsch and Prufung BAM, Germany.
Bundesanstalt Mat Forsch and Prufung BAM, Germany; Fraunhofer Wilhelm Klauditz Inst, Germany.
Vise andre og tillknytning
2018 (engelsk)Inngår i: Sensors and actuators. B, Chemical, ISSN 0925-4005, E-ISSN 1873-3077, Vol. 273, s. 1037-1046Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

In this work, we use a gas sensor system consisting of a commercially available gas sensor in temperature cycled operation. It is trained with an extensive gas profile for detection and quantification of hazardous volatile organic compounds (VOC) in the ppb range independent of a varying background of other, less harmful VOCs and inorganic interfering gases like humidity or hydrogen. This training was then validated using a different gas mixture generation apparatus at an independent lab providing analytical methods as reference. While the varying background impedes selective detection of benzene and naphthalene at the low concentrations supplied, both formaldehyde and total VOC can well be quantified, after calibration transfer, by models trained with data from one system and evaluated with data from the other system. The lowest achievable root mean squared errors of prediction were 49 ppb for formaldehyde (in a concentration range of 20-200 ppb) and 150 mu g/m(3) (in a concentration range of 25-450 mu g/m(3)) for total VOC. The latter uncertainty improves to 13 mu g/m(3) with a more confined model range of 220-320 mu g/m(3). The data from the second lab indicate an interfering gas which cannot be detected analytically but strongly influences the sensor signal. This demonstrates the need to take into account all sensor relevant gases, like, e.g., hydrogen and carbon monoxide, in analytical reference measurements.

sted, utgiver, år, opplag, sider
ELSEVIER SCIENCE SA , 2018. Vol. 273, s. 1037-1046
Emneord [en]
Indoor air quality; Volatile organic compounds; Calibration transfer; Selective quantification; Inter-lab comparison
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-150838DOI: 10.1016/j.snb.2018.06.097ISI: 000441519000130OAI: oai:DiVA.org:liu-150838DiVA, id: diva2:1245928
Merknad

Funding Agencies|European Union [604311]

Tilgjengelig fra: 2018-09-06 Laget: 2018-09-06 Sist oppdatert: 2018-09-06

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Søk i DiVA

Av forfatter/redaktør
Bastuck, Manuel
Av organisasjonen
I samme tidsskrift
Sensors and actuators. B, Chemical

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 406 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf