Quality assurance for magnetic resonance imaging (MRI) in radiotherapy
Umeå University, Faculty of Medicine, Department of Radiation Sciences.ORCID iD: 0000-0003-3217-3208
2017 (English)Licentiate thesis, comprehensive summary (Other academic)
Abstract [en]

Magnetic resonance imaging (MRI) utilizes the magnetic properties of tissues to generate image-forming signals. MRI has exquisite soft-tissue contrast and since tumors are mainly soft-tissues, it offers improved delineation of the target volume and nearby organs at risk. The proposed Magnetic Resonance-only Radiotherapy (MR-only RT) work flow allows for the use of MRI as the sole imaging modality in the radiotherapy (RT) treatment planning of cancer. There are, however, issues with geometric distortions inherent with MR image acquisition processes. These distortions result from imperfections in the main magnetic field, nonlinear gradients, as well as field disturbances introduced by the imaged object. In this thesis, we quantified the effect of system related and patient-induced susceptibility geometric distortions on dose distributions for prostate as well as head and neck cancers. Methods to mitigate these distortions were also studied.

In Study I, mean worst system related residual distortions of 3.19, 2.52 and 2.08 mm at bandwidths (BW) of 122, 244 and 488 Hz/pixel up to a radial distance of 25 cm from a 3T PET/MR scanner was measured with a large field of view (FoV) phantom. Subsequently, we estimated maximum shifts of 5.8, 2.9 and 1.5 mm due to patient-induced susceptibility distortions. VMAT-optimized treatment plans initially performed on distorted CT (dCT) images and recalculated on real CT datasets resulted in a dose difference of less than 0.5%.

 The magnetic susceptibility differences at tissue-metallic,-air and -bone interfaces result in local B0 magnetic field inhomogeneities. The distortion shifts caused by these field inhomogeneities can be reduced by shimming.  Study II aimed to investigate the use of shimming to improve the homogeneity of local  B0 magnetic field which will be beneficial for radiotherapy applications. A shimming simulation based on spherical harmonics modeling was developed. The spinal cord, an organ at risk is surrounded by bone and in close proximity to the lungs may have high susceptibility differences. In this region, mean pixel shifts caused by local B0 field inhomogeneities were reduced from 3.47±1.22 mm to 1.35±0.44 mm and 0.99±0.30 mm using first and second order shimming respectively. This was for a bandwidth of 122 Hz/pixel and an in-plane voxel size of 1×1 mm2.  Also examined in Study II as in Study I was the dosimetric effect of geometric distortions on 21 Head and Neck cancer treatment plans. The dose difference in D50 at the PTV between distorted CT and real CT plans was less than 1.0%.

In conclusion, the effect of MR geometric distortions on dose plans was small. Generally, we found patient-induced susceptibility distortions were larger compared with residual system distortions at all delineated structures except the external contour. This information will be relevant when setting margins for treatment volumes and organs at risk.  

The current practice of characterizing MR geometric distortions utilizing spatial accuracy phantoms alone may not be enough for an MR-only radiotherapy workflow. Therefore, measures to mitigate patient-induced susceptibility effects in clinical practice such as patient-specific correction algorithms are needed to complement existing distortion reduction methods such as high acquisition bandwidth and shimming.

Place, publisher, year, edition, pages
Umeå: Department of radiation sciences, Umeå university , 2017. , p. 54
Series
Umeå University medical dissertations, ISSN 0346-6612
Keywords [en]
Magnetic resonance imaging, Radiotherapy, geometric distortions, patient-induced susceptibilities MR-only
National Category
Radiology, Nuclear Medicine and Medical Imaging Other Physics Topics Medical Image Processing
Research subject
radiation physics
Identifiers
URN: urn:nbn:se:umu:diva-142603ISBN: 978-91-7601-797-5 (print)OAI: oai:DiVA.org:umu-142603DiVA, id: diva2:1162983
Presentation
2017-12-20, Bergasalen, Byggnad 27, Umeå, 09:00 (English)
Opponent
Supervisors
Available from: 2017-12-11 Created: 2017-12-05 Last updated: 2019-11-05Bibliographically approved

Open Access in DiVA

fulltext(1392 kB)1517 downloads
File information
File name FULLTEXT02.pdfFile size 1392 kBChecksum SHA-512
376ed0b1b99819ae02582ae8165816ea33fba60e6e3eb309a3ce786f86fc40b4d6c49dce55b9ce9afd59b8d9645c82a45a14d4478cda41ec6409f2084491c28a
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Adjeiwaah, Mary
By organisation
Department of Radiation Sciences
Radiology, Nuclear Medicine and Medical ImagingOther Physics TopicsMedical Image Processing

Search outside of DiVA

GoogleGoogle Scholar
Total: 1517 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 2856 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf