Failure Modes Demonstration and Redundant Postfault Operation of Rotating Thyristor Rectifiers on Brushless Dual-Star Exciters
Department of Microsystems, University of South-Eastern Norway, Borre, Norway.ORCID iD: 0000-0002-3656-1032
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences, Electricity.ORCID iD: 0000-0001-8237-3107
Department of Microsystems, University of South-Eastern Norway, Borre, Norway.ORCID iD: 0000-0002-9412-4383
2019 (English)In: IEEE Transactions on Industrial Electronics, ISSN 0278-0046, E-ISSN 1557-9948, Vol. 66, no 2, p. 842-851Article in journal (Refereed) Published
Abstract [en]

The excitation system plays a critical role in the operation of synchronous generators. An equipment failure could impact the voltage quality for smaller grids. Further, it can lead to cost penalties and reduced production for the power plant owner. Recently, a new high-speed-response rotating brushless exciter was developed that employs remote control of the rotating thyristors on the generator shaft. This has led to new possibilities for improving the performance of brushless exciters. This contribution investigates the failure modes of a dual-star outer pole exciter that feeds two separate thyristor bridges connected in parallel during normal operation. The possibility of redundant postfault operation due to open-thyristor or open-phase faults are demonstrated using experimental testing. The system is compared with the fault performance of a conventional three-phase system. This work includes the implementation and validation of a fault-predicting double d-q exciter model. In addition, the dangerous effects of a shorted-thyristor fault are investigated. A "skip firing" protection technique is briefly demonstrated for the fast isolation of such faults, yielding nondestructive postfault recovery and redundant failure-mode operation. The evidence shows that the dual-star exciter is a competitive choice for the future development of fault-tolerant brushless exciters.

Place, publisher, year, edition, pages
2019. Vol. 66, no 2, p. 842-851
Keywords [en]
Brushless exciters, double-star windings, dual-port electrical machines, 12-pulse thyristor bridges, open-phase faults, open-thyristor faults, shorted thyristors
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Research subject
Engineering Science with specialization in Science of Electricity
Identifiers
URN: urn:nbn:se:uu:diva-333567DOI: 10.1109/TIE.2018.2833044ISI: 000446340800002OAI: oai:DiVA.org:uu-333567DiVA, id: diva2:1157152
Note

Title in thesis list of papers (Nøland): Failure-Modes of a Thyristor-Controlled Six-Phase Rotating Brushless Outer Pole PM Exciter with 12-Pulse Hybrid-Mode Operation

Available from: 2017-11-15 Created: 2017-11-15 Last updated: 2023-08-28Bibliographically approved
In thesis
1. Improving the functionality of synchronous machines using power electronics
Open this publication in new window or tab >>Improving the functionality of synchronous machines using power electronics
2017 (English)Licentiate thesis, comprehensive summary (Other academic)
Abstract [en]

With the advent of modern power electronics there is reason to explore what can be achieved when it is applied to a mature technology like synchronous machines. In this text several concepts will be presented on how it is possible to control forces and how to get better performance out of synchronous machines by using power electronics. Methodologies to create radial forces by controlling the field current in a standard series connected rotor winding as well as when the winding is split in to several segments is presented. By segmenting the rotor a resulting force vector can be created to cancel forces due to unbalanced magnetic pull.

It is also shown that inverting the field current with respect to the stator field enables line start of synchronous machines without using damper bars, frequency converters, or starting motors.

Some first results from the installation and testing of an electromagnetic thrust bearing installed in unit U9 in the hydropower station in Porjus are presented. The benefits of the system is increased reliability and higher efficiency of the thrust bearing system.

An evaluation of a 2-stage brushless excitation system was done, different rotating power electronics topologies were tested in the stationary frame connected to a six-phase permanent magnet brushless exciter. The rotating control and measurement system for the power electronics is presented. Potential benefits of the system is that there is no need for brushes to transfer the field current to the rotor winding, fast response time due to actively controlled electronics, independence of the station bus voltage, and reduced maintenance.

Place, publisher, year, edition, pages
Uppsala: Acta Universitatis Upsaliensis, 2017
Series
UURIE / Uppsala University, Department of Engineering Sciences, ISSN 0349-8352 ; 352-17L
Keywords
Power electronics, Synchronous machines, Excitation systems, Magnetic thrust bearing, Starting synchronous machines, Split rotor, Rotating electronics, Magnetic fields, Measurement systems, Unbalanced magnetic pull, Harmonics
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Research subject
Engineering Science with specialization in Science of Electricity
Identifiers
urn:nbn:se:uu:diva-333940 (URN)
Presentation
2017-12-18, Häggsalen (Å10132), Ångströmslaboratoriet, Lägerhyddsvägen 1, Uppsala, 10:15 (English)
Opponent
Supervisors
Available from: 2018-01-08 Created: 2017-11-20 Last updated: 2018-01-08Bibliographically approved
2. A New Paradigm for Large Brushless Hydrogenerators: Advantages Beyond the Static System
Open this publication in new window or tab >>A New Paradigm for Large Brushless Hydrogenerators: Advantages Beyond the Static System
2017 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

The grid code, FIKS, from the Norwegian transmission system operator (TSO), Statnett, states that synchronous generators > 25MVA, must have a static excitation system. However, an improved brushless excitation system is in operation on some commercial power plants (36MVA, 93.75rpm & 52MVA, 166.67rpm) with grid-assisting performance beyond the conventional static system. The convenional diode bridge is replaced with a remote-controlled thyristor bridge on the shaft. If wireless communication is not allowed, a control signal through brushes should be employed instead. The thesis explores the expected new era for large brushless hydrogenerators. The proposed brushless system have benefits of reduced regular maintenance due to elimination of brushes and reduced unscheduled maintenance due to redundancy; causing a redused cost-of-energy. A six-phase exciter design with a hybrid-mode thyristor bridge interface leads to improved fault-tolerance, better controllability, minimized torque pulsations and reduced armature currents of the exciter. Excitation boosting (EB) capability is included in the brushless system without additional components or circuitry, contrary to the static excitation system. The brushless excitation system is made insensitive to voltage dips in the interconnected grid, causing improved fault ride-through (FRT) capability and power system stabilizer (PSS) actions. 

Place, publisher, year, edition, pages
Uppsala: Acta Universitatis Upsaliensis, 2017. p. 93
Series
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, ISSN 1651-6214 ; 1491
Keywords
Brushless exciters, Rotating exciters, Permanent Magnet Machines, Synchronous Generator Excitation, Thyristor Rectifiers, Chopper Rectifiers
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Research subject
Engineering Science with specialization in Science of Electricity
Identifiers
urn:nbn:se:uu:diva-317780 (URN)978-91-554-9859-7 (ISBN)
Public defence
2017-05-10, Häggsalen, Ångströmlaboratoriet, Polacksbacken, Lägerhyddsvägen 2, Uppsala, 13:00 (English)
Opponent
Supervisors
Available from: 2017-04-19 Created: 2017-03-17 Last updated: 2019-05-13

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full texthttps://ieeexplore.ieee.org/document/8353791/

Search in DiVA

By author/editor
Nøland, Jonas KristiansenEvestedt, FredrikLundin, Urban
By organisation
Electricity
In the same journal
IEEE Transactions on Industrial Electronics
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 2241 hits
CiteExportLink to record
Permanent link

Direct link