Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
An echo-planar imaging sequence is superior to a steady-state free precession sequence for visual as well as quantitative assessment of cardiac magnetic resonance stress perfusion
Department of Radiology, Ryhov County Hospital, Jönköping, Sweden.
Department of Radiology, Ryhov County Hospital, Jönköping, Sweden.
Department of Clinical Physiology, Kalmar County Hospital, Kalmar, Sweden.
Högskolan i Jönköping, Hälsohögskolan, HHJ, Avd. för naturvetenskap och biomedicin. Department of Oncology, Hospital Physics, Ryhov County Hospital, Jönköping, Sweden.ORCID-id: 0000-0002-3951-7715
Visa övriga samt affilieringar
2017 (Engelska)Ingår i: Clinical Physiology and Functional Imaging, ISSN 1475-0961, E-ISSN 1475-097X, Vol. 37, nr 1, s. 52-61Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background: To assess myocardial perfusion, steady-state free precession cardiac magnetic resonance (SSFP, CMR) was compared with gradient-echo–echo-planar imaging (GRE-EPI) using myocardial perfusion scintigraphy (MPS) as reference.

Methods: Cardiac magnetic resonance perfusion was recorded in 30 patients with SSFP and in another 30 patients with GRE-EPI. Timing and extent of inflow delay to the myocardium was visually assessed. Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were calculated. Myocardial scar was visualized with a phase-sensitive inversion recovery sequence (PSIR). All scar positive segments were considered pathologic. In MPS, stress and rest images were used as in clinical reporting. The CMR contrast wash-in slope was calculated and compared with the stress score from the MPS examination. CMR scar, CMR perfusion and MPS were assessed separately by one expert for each method who was blinded to other aspects of the study.

Results: Visual assessment of CMR had a sensitivity for the detection of an abnormal MPS at 78% (SSFP) versus 91% (GRE-EPI) and a specificity of 58% (SSFP) versus 84% (GRE-EPI). Kappa statistics for SSFP and MPS was 0·29, for GRE-EPI and MPS 0·72. The ANOVA of CMR perfusion slopes for all segments versus MPS score (four levels based on MPS) had correlation r = 0·64 (SSFP) and r = 0·96 (GRE-EPI). SNR was for normal segments 35·63 ± 11·80 (SSFP) and 17·98 ± 8·31 (GRE-EPI), while CNR was 28·79 ± 10·43 (SSFP) and 13·06 ± 7·61 (GRE-EPI).

Conclusion: GRE-EPI displayed higher agreement with the MPS results than SSFP despite significantly lower signal intensity, SNR and CNR.

Ort, förlag, år, upplaga, sidor
Wiley-Blackwell, 2017. Vol. 37, nr 1, s. 52-61
Nyckelord [en]
cardiac imaging techniques, coronary heart disease, Magnetic Resonance Imaging, nuclear medicine, perfusion
Nationell ämneskategori
Kardiologi
Identifikatorer
URN: urn:nbn:se:hj:diva-34807DOI: 10.1111/cpf.12267ISI: 000390688200008PubMedID: 26147785Scopus ID: 2-s2.0-84936803283OAI: oai:DiVA.org:hj-34807DiVA, id: diva2:1067098
Tillgänglig från: 2017-01-20 Skapad: 2017-01-20 Senast uppdaterad: 2017-11-29Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Sök vidare i DiVA

Av författaren/redaktören
Starck, Sven-Åke
Av organisationen
HHJ, Avd. för naturvetenskap och biomedicin
I samma tidskrift
Clinical Physiology and Functional Imaging
Kardiologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 433 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf