Acceptance Tests – FAT & SAT: An Empirical Case Study of Utility Poles
Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Logistik- och kvalitetsutveckling.
2016 (engelsk)Independent thesis Advanced level (degree of Master (Two Years)), 80 poäng / 120 hpOppgave
Abstract [en]

The overall purpose of this project is to devise improved quality acceptance procedures to examine quality characteristics of utility poles at the factory of the supplier (FAT) and on-site upon receipt by the customer (SAT). To that end, the thesis draws upon available standards, literature, and industry practices regarding wood, fiberglass and steel poles. As far as the design of the research, a single case study of a major power company was chosen. Then, a data collection plan was developed in order to build upon the existing knowledge found in the literature, and upon the data that can be collected from three of the Company’s suppliers, in addition to the Technical Research Institute of Sweden (SP). Documents’ analysis, interviews, observations, and a survey were the tools of that plan. It was found that criteria, inspection and test methods of wood poles are all sufficiently covered in the standards and the literature; for wood is the most commonly used material for utility poles. Next, in coverage of research, are the steel poles; while there is currently no standard that covers fiberglass utility poles. Indeed, quality characteristics, criteria, and acceptance procedures can altogether form parts of a sustainable solution, as long as the quality is managed as a process whether at the Company’s end or at the fabrication sites; that is especially true if there is some form of backward partnership between the Company and its suppliers.

sted, utgiver, år, opplag, sider
2016. , s. 82
Emneord [en]
Factory acceptance test, quality control, quality inspection, utility poles, quality management
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-132288ISRN: LIU-IEI-TEK-A--16/02698--SEOAI: oai:DiVA.org:liu-132288DiVA, id: diva2:1040268
Eksternt samarbeid
Vattenfall Eldistribution AB
Fag / kurs
Industrial Management
Presentation
2016-10-21, Brage 2B:853, SE-581 83, Linköping, 20:43 (engelsk)
Veileder
Examiner
Tilgjengelig fra: 2016-11-02 Laget: 2016-10-26 Sist oppdatert: 2016-11-02bibliografisk kontrollert

Open Access i DiVA

fulltext(6736 kB)9038 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 6736 kBChecksum SHA-512
8622313c9bd6f2b81ea4cbaaa43e539f0d82945c003b296772cb6c66cf16adf17a42689a4a50c3e77fb5e2f2625e7294181878d8cb7da818e38e0b50e660052a
Type fulltextMimetype application/pdf

Søk i DiVA

Av forfatter/redaktør
Al Farra, Hussni
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 9053 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 22952 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf