Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Validity and Responsiveness of At-Home Touch Screen Assessments in Advanced Parkinson's Disease
Dalarna Univ, Sch Technol & Business Studies, Comp Engn, S-79188 Falun, Sweden..
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för neurovetenskap, Neurologi.
Karolinska Inst, Dept Clin Neurosci, Neurol, S-14186 Huddinge, Sweden..
Karolinska Univ Hosp, Dept Neurol, S-17177 Stockholm, Sweden..
Visa övriga samt affilieringar
2015 (Engelska)Ingår i: IEEE journal of biomedical and health informatics, ISSN 2168-2194, E-ISSN 2168-2208, Vol. 19, nr 6, s. 1829-1834Artikel i tidskrift (Refereegranskat) Published
Resurstyp
Text
Abstract [en]

The aim of this study was to investigate if a telemetry test battery can be used to measure effects of Parkinson's disease (PD) treatment intervention and disease progression in patients with fluctuations. Sixty-five patients diagnosed with advanced PD were recruited in an open longitudinal 36-month study; 35 treated with levodopa-carbidopa intestinal gel (LCIG) and 30 were candidates for switching from oral PD treatment to LCIG. They utilized a test battery, consisting of self-assessments of symptoms and fine motor tests (tapping and spiral drawings), four times per day in their homes during week-long test periods. The repeated measurements were summarized into an overall test score (OTS) to represent the global condition of the patient during a test period. Clinical assessments included ratings on unified PD rating scale (UPDRS) and 39-item PD questionnaire (PDQ-39) scales. In LCIG-naive patients, the mean OTS compared to baseline was significantly improved from the first test period on LCIG treatment until month 24. In LCIG-non naive patients, there were no significant changes in the mean OTS until month 36. The OTS correlated adequately with total UPDRS (rho = 0.59) and total PDQ-39 (0.59). Responsiveness measured as effect size was 0.696 and 0.536 for OTS and UPDRS, respectively. The trends of the test scores were similar to the trends of clinical rating scores but the dropout rate was high. Correlations betweenOTS and clinical rating scales were adequate indicating that the test battery contains important elements of the information of well-established scales. The responsiveness and reproducibility were better for OTS than for total UPDRS.

Ort, förlag, år, upplaga, sidor
2015. Vol. 19, nr 6, s. 1829-1834
Nyckelord [en]
Home assessment, levodopa infusion, Parkinson's, disease (PD), remote monitoring, telemedicine.
Nationell ämneskategori
Medicinsk bioteknologi
Identifikatorer
URN: urn:nbn:se:uu:diva-269978DOI: 10.1109/JBHI.2015.2468088ISI: 000364857000007PubMedID: 26285227OAI: oai:DiVA.org:uu-269978DiVA, id: diva2:885598
Tillgänglig från: 2015-12-19 Skapad: 2015-12-19 Senast uppdaterad: 2017-12-01Bibliografiskt granskad

Open Access i DiVA

fulltext(602 kB)178 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 602 kBChecksumma SHA-512
d344274b80ab6b294065206d91075431cd1b28c80c96b7aa92ae2a800f2555f78a65ef9004ac77a9935fb69fc9349e061ba1ff3b442b52335c0bcb1f94a819d7
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMed

Sök vidare i DiVA

Av författaren/redaktören
Nyholm, Dag
Av organisationen
Neurologi
I samma tidskrift
IEEE journal of biomedical and health informatics
Medicinsk bioteknologi

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 178 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 643 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf