Undersökning av tryckfall relaterat till avstånd mellan två 90 graders krökar i cirkulär ventilationskanal
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik.
2015 (Svenska)Självständigt arbete på grundnivå (högskoleexamen), 10 poäng / 15 hpStudentuppsats (Examensarbete)
Abstract [en]

Due to higher standards of living around the world, greater industries and larger infrastructures causes an increase of the global energy consumption. This harvest of energy puts a great stress on the global environment. With this development, it becomes increasingly important to utilize energy resources in the best possible way.

Fans are components that are often used in the industry and in households. A common problem is that the fan is oversized. An oversized fan causes an excessive flow, which has to be adjusted in order to achieve the correct flow. This results in larger energy usage than the use of a properly sized fan. When designing a ventilation system calculations have to be made in order to determine the total pressure loss of the system. A series of simplifications are applied when using theoretical calculations. The total pressure loss of the system is assumed to be the sum of the pressure loss of each component in the system. This simplification ignores the separation distance that exists between each component. In reality, when air passes through the components, swirls emerge and a distortion of the velocity profile occurs. This causes large pressure losses due to friction losses occurring between the fluid and the pipe wall. The recommendation given in HVAC installations states that two 90 degree elbows should not be placed closer to each other than 6D (D representing the hydraulic diameter of the pipe) to thereby prevent large pressure drops.

This dissertation will address the following questions:

  • The recommendation in HVAC installations states that two 90 degree elbows should not be placed closer to each other than 6D (D representing the hydraulic diameter of the pipe) to thereby prevent large pressure drops. Does this recommendation conform with the empirical data obtained from conducted experiments?

  •  What is the relation between the pressure drop and the separation distance between two 90 degree elbows?

    In this dissertation a series of experiments are conducted where pressure loss measurements are made within a circular ventilation duct with two integrated 90 degree elbows. Pressure loss measurements within a U-shaped piping system are made at five different fluid velocities each at 11 different separation distances between the two 90 degree elbows. By analysis of the obtained empirical data and by comparing it to the recommendation no results were found to validate this statement. 

Ort, förlag, år, upplaga, sidor
2015. , s. 56
Nyckelord [en]
pressure drop, separation distance, 90 degree elbow, energy
Nyckelord [sv]
tryckfall, separationsavstånd, 90 graders krök, energi
Nationell ämneskategori
Teknik och teknologier
Identifikatorer
URN: urn:nbn:se:hig:diva-19605OAI: oai:DiVA.org:hig-19605DiVA, id: diva2:820470
Ämne / kurs
Energisystem
Utbildningsprogram
Energisystem – kandidatprogram (på eng)
Presentation
(Svenska)
Handledare
Examinatorer
Tillgänglig från: 2015-06-15 Skapad: 2015-06-12 Senast uppdaterad: 2015-06-15Bibliografiskt granskad

Open Access i DiVA

fulltext(2068 kB)2557 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 2068 kBChecksumma SHA-512
5a23c6b08c0074264d5c7b27faf0cc39bb1b9c3403d13314a531ecca05644742575ef7678d8632bb2008a50d57e05ae11dfbc9df542d5df7d39b179d2fa59039
Typ fulltextMimetyp application/pdf

Sök vidare i DiVA

Av författaren/redaktören
Kellner, Philip
Av organisationen
Avdelningen för bygg- energi- och miljöteknik
Teknik och teknologier

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 2565 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 287 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf