Assessment of the in vivo biomechanical properties of the human uterine cervix in pregnancy using the aspiration test A feasibility study
Visa övriga samt affilieringar
2009 (Engelska)Ingår i: European Journal of Obstetrics, Gynecology, and Reproductive Biology, ISSN 0301-2115, E-ISSN 1872-7654, Vol. 144, s. S77-S81Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Objective: To date no diagnostic tool is yet available to objectively assess the in vivo biomechanical properties of the uterine cervix during gestation. Methods: We show the first clinical application of an aspiration device to assess the in vivo biomechanical properties of the cervix in pregnancy with the aim to describe the physiological biomechanical changes throughout gestation in order to eventually detect pregnant women at risk for cervical insufficiency (CI). Results: Out of 15 aspiration measurements, 12 produced valid results. The stiffness values were in the range between 0.013 and 0.068 bar/mm. The results showed a good reproducibility of the aspiration test. In our previous test series on non-pregnant cervices our repetitive measurements showed a standard deviation of > 20% compared to <+/- 10% to our data on pregnant cervices. Stiffness values are decreasing with gestational age which indicates a progressive softening of cervical tissue towards the end of pregnancy. Three pregnant women had two subsequent measurements within a time interval of four weeks. Decreasing stiffness values in the range of 20% were recorded. Discussion: This preliminary study on the clinical practicability of aspiration tests showed promising results in terms of reproducibility (reliability) and clinical use (feasibility). Ongoing studies will provide further insights on its usefulness in clinical practice and in the detection of substantial changes of the cervix in pregnancy indicative for threatened preterm birth or cervical insufficiency.

Ort, förlag, år, upplaga, sidor
2009. Vol. 144, s. S77-S81
Nyckelord [en]
Uterine cervix, Remodeling, Mechanical properties, Biomechanics, Aspiration device, In vivo, Pregnancy, Stiffness
Nationell ämneskategori
Medicinsk laboratorie- och mätteknik
Identifikatorer
URN: urn:nbn:se:kth:diva-30871DOI: 10.1016/j.ejogrb.2009.02.025ISI: 000265518400013PubMedID: 19285777Scopus ID: 2-s2.0-67650134517OAI: oai:DiVA.org:kth-30871DiVA, id: diva2:401976
Anmärkning
QC 20110304Tillgänglig från: 2011-03-04 Skapad: 2011-03-04 Senast uppdaterad: 2024-01-08Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Sök vidare i DiVA

Av författaren/redaktören
Holzapfel, Gerhard A.
Av organisationen
Hållfasthetslära (Avd.)
I samma tidskrift
European Journal of Obstetrics, Gynecology, and Reproductive Biology
Medicinsk laboratorie- och mätteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 637 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf