Dielectric response and partial discharge measurements on stator insulation at varied low frequency
KTH, Skolan för elektro- och systemteknik (EES), Elektroteknisk teori och konstruktion. (High voltage engineering and insulation diagnostics)ORCID-id: 0000-0003-0759-4406
2010 (Engelska)Doktorsavhandling, monografi (Övrigt vetenskapligt)
Abstract [en]

This is a study of potential improvements of diagnostic methods used on high-voltage generators and motors.  It considers offline electrical measurements on the main insulation of stator windings, where a sinusoidal voltage is applied between the winding and the stator-core, and the total current through the insulation (dielectric spectroscopy, DS) and the rapid current-pulses arising from discharges (partial discharge, PD) are measured.

The proposed methods differ from existing practice in industrial DS and PD measurements in that the applied voltage is varied in amplitude and in frequency, harmonics of the voltage and current are measured, and the DS and PD measurements are made simultaneously, with comparison of results.  Based on literature, models and measurements, the problems and advantages of these methods are assessed in this work.

Harmonics provide a way of separating linear and nonlinear sources of current, and reveal the waveform of the current.  Measurement of total PD charge by DS methods provides complementary information to the conventional PD measurement; the difference in results between these types of measurement is shown by literature and experimental results to be large.  Simultaneous measurement allows direct comparison of the relation between the DS and PD results, and saves time compared to separate measurements.  The varied frequency, down to the millihertz range, provides additional information about the insulation.  Much of the potential for DS methods on machine insulation is spoiled by the end-winding stress grading.  Models and measurements of the currents in this grading are presented, with discussion of how much effect the disturbance has and how well it can be predicted by modelling.

Ort, förlag, år, upplaga, sidor
Stockholm: KTH , 2010. , s. xxi, 261
Serie
Trita-EE, ISSN 1653-5146 ; 2010:037
Nationell ämneskategori
Annan elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:kth:diva-24359ISBN: 978-91-7415-713-0 (tryckt)OAI: oai:DiVA.org:kth-24359DiVA, id: diva2:347906
Disputation
2010-09-24, F3, Lindstedtsvägen 26, KTH, Stockholm, 10:00 (Engelska)
Opponent
Handledare
Anmärkning
QC 20100906Tillgänglig från: 2010-09-06 Skapad: 2010-09-03 Senast uppdaterad: 2010-09-06Bibliografiskt granskad

Open Access i DiVA

fulltext(5166 kB)1961 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 5166 kBChecksumma SHA-512
fea190b94241d87a873e8bf8cd84dffb6f2e1826854a754c5e7c487aef974203fe3324cfb900561ab8fcd0a5a9ea8587b393ccaccdded398e5122b730291a962
Typ fulltextMimetyp application/pdf

Sök vidare i DiVA

Av författaren/redaktören
Taylor, Nathaniel
Av organisationen
Elektroteknisk teori och konstruktion
Annan elektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 1961 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

isbn
urn-nbn

Altmetricpoäng

isbn
urn-nbn
Totalt: 1408 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf