The Effect of High Occupancy Density on IAQ, Moisture Conditions and Energy Use in Apartments
RISE - Research Institutes of Sweden, Samhällsbyggnad. Lund University, Sweden.ORCID-id: 0000-0002-3863-0740
Lund University, Sweden.
Lund University, Sweden.
2019 (Engelska)Ingår i: Energies, ISSN 1996-1073, E-ISSN 1996-1073, Vol. 12, nr 23, artikel-id 4454Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Apartments built in Sweden during the record years 1961–1975 with the aim to remedy thehousing shortage and abolish poor standards, were designed for a normal-sized family of 2–4 persons.The mechanical ventilation system, if existing, was primarily designed to ensure an air exchange inthe apartment according to Swedish building regulations. During the last few years, the number ofovercrowded apartments has increased due to housing shortage in general but also due to migration.Another aspect is that the ventilation in many apartments built during the record years is alreadyinsucient at normal occupant load. The question is how doubling or tripling the number ofoccupants and thus, the moisture load will aect the risk of bad air quality and moisture damage.To find out, simulations were made to estimate whether it is possible to obtain sucient air qualityand low risk of moisture damage by only increasing the ventilation rates in existing systems orintroducing new ventilation systems with and without heat recovery and what the consequencewould be in terms of the additional energy demand. Measurements from earlier studies of CO2 andmoisture supply in Swedish apartment buildings were used as input data.

Ort, förlag, år, upplaga, sidor
2019. Vol. 12, nr 23, artikel-id 4454
Nyckelord [en]
occupancy density; moisture conditions; energy use; indoor air quality; ventilation rate
Nationell ämneskategori
Naturvetenskap
Identifikatorer
URN: urn:nbn:se:ri:diva-40853DOI: 10.3390/en12234454OAI: oai:DiVA.org:ri-40853DiVA, id: diva2:1372360
Anmärkning

(This article belongs to the Special Issue Energy and Technical Building Systems - Scientific and Technological Advances)

Tillgänglig från: 2019-11-22 Skapad: 2019-11-22 Senast uppdaterad: 2019-11-22Bibliografiskt granskad

Open Access i DiVA

fulltext(2299 kB)25 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 2299 kBChecksumma SHA-512
6514a250519b681fa74af3336276ebb9ea4f8d1f504f9d3f1d102e93ff7a993188e3195fb48e464536bbb413259bb8bc101b00ee570c73e0b9ea4fe282203bb8
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltext

Sök vidare i DiVA

Av författaren/redaktören
Mjörnell, Kristina
Av organisationen
Samhällsbyggnad
I samma tidskrift
Energies
Naturvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 25 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 19 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf