Identification of optimum molten salts for use as heat transfer fluids in parabolic trough CSP plants. A techno-economic comparative optimization
KTH, Skolan för industriell teknik och management (ITM), Energiteknik.
Visa övriga samt affilieringar
2017 (Engelska)Ingår i: AIP Conference Proceedings, ISSN 0094-243X, E-ISSN 1551-7616Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Parabolic trough power plants using thermal oil as heat transfer fluid are the most mature concentrating solar power technology and state of the art. To further increase their efficiency and lower costs, molten salts can be used as heat transfer fluid. This results in higher operating temperature differences for improved cycle efficiencies and enables direct thermal energy storage at lower costs due to omission of the oil-to-salt heat exchanger and the need for smaller storage sizes. As a variety of salts are available to choose from, this study uses a multi-objective optimization to identify the most suitable heat transfer fluid for three locations in South Africa, Spain and Chile. The lowest values for the levelized costs of electricity (LCOE) can be found in Chile using Solar Salt as heat transfer fluid (75.0 $/MWhe). Generally, Solar Salt offers the lowest LCOE values followed by thermal oil and Hitec. The results also suggest that the choice of the heat transfer fluid is dependent on the direct normal irradiance (DNI) at each location. Thermal oil is competitive with Solar Salt in small systems at locations with low DNI values, whereas Hitec can be cheaper than thermal oil in large systems at locations with high DNI. Furthermore, it is also investigated at which freeze alert temperature set point the activation of the freeze protection system is optimal. The results indicate that this temperature should be chosen close to the solar field inlet temperature for small systems, while it can be lowered significantly for large systems to reduce electricity consumption from the freeze protection system.

Ort, förlag, år, upplaga, sidor
American Institute of Physics (AIP), 2017.
Nationell ämneskategori
Energiteknik
Identifikatorer
URN: urn:nbn:se:kth:diva-250235DOI: 10.1063/1.5067028ISI: 000481681200019Scopus ID: 2-s2.0-85057123580ISBN: 978-0-7354-1757-1 (digital)OAI: oai:DiVA.org:kth-250235DiVA, id: diva2:1307258
Konferens
SolarPACES 2017
Anmärkning

QC 20190420

Tillgänglig från: 2019-04-26 Skapad: 2019-04-26 Senast uppdaterad: 2019-09-05Bibliografiskt granskad

Open Access i DiVA

fulltext(1238 kB)155 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 1238 kBChecksumma SHA-512
982e930639b36c76515a4a6d46856af47d0310bf94e036771bbba2316d494829690a9a7104b0e8f1c6ed2981136835348d144b60126d41364570be35646415ba
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextScopus

Sök vidare i DiVA

Av författaren/redaktören
Guédez, RafaelLaumert, Björn
Av organisationen
EnergiteknikKraft- och värmeteknologi
I samma tidskrift
AIP Conference Proceedings
Energiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 155 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
isbn
urn-nbn

Altmetricpoäng

doi
isbn
urn-nbn
Totalt: 486 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf