Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Left atrial volumetric assessment using a novel automated framework for 3D echocardiography: a multi-centre analysis
Katholieke University of Leuven, Belgium; GE Vingmed Ultrasound AS, Norway.
Kings Coll Hospital London, England.
Kings Coll Hospital London, England.
University of Oslo, Norway.
Visa övriga samt affilieringar
2017 (Engelska)Ingår i: European Heart Journal Cardiovascular Imaging, ISSN 2047-2404, E-ISSN 2047-2412, Vol. 18, nr 9, s. 1008-1015Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Aims This study aims at validating a software tool for automated segmentation and quantification of the left atrium (LA) from 3D echocardiography. Methods and results The LA segmentation tool uses a dual-chamber model of the left side of the heart to automatically detect and track the atrio-ventricular plane and the LA endocardium in transthoracic 3D echocardiography. The tool was tested in a dataset of 121 ultrasound images from patients with several cardiovascular pathologies (in a multi-centre setting), and the resulting volumes were compared with those assessed manually by experts in a blinded analysis using conventional contouring. Bland-Altman analysis showed good agreement between the automated method and the manual references, with differences (mean +/- 1.96 SD) of 0.5 +/- 5.7 mL for LA minimum volume and -1.6 +/- 9.7 mL for LA maximum volume (comparable to the inter-observer variability of manual tracings). The automated tool required no user interaction in 93% of the recordings, while 4% required a single click and only 2% required contour adjustments, reducing considerably the amount of time and effort required for LA volumetric analysis. Conclusion The automated tool was validated in a multi-centre setting, providing quantification of the LA volume over the cardiac cycle with minimal user interaction. The results of the automated analysis were in agreement with those estimated manually by experts. This study shows that such approach has clinical utility for the assessment of the LA morphology and function, automating and facilitating the time-consuming task of analysing 3D echocardiographic recordings.

Ort, förlag, år, upplaga, sidor
OXFORD UNIV PRESS , 2017. Vol. 18, nr 9, s. 1008-1015
Nyckelord [en]
left atrium assessment; automated analysis; RT3DE; 3D echocardiography; volumetric function assessment
Nationell ämneskategori
Medicinsk laboratorie- och mätteknik
Identifikatorer
URN: urn:nbn:se:liu:diva-140501DOI: 10.1093/ehjci/jew166ISI: 000408090700009PubMedID: 27550659OAI: oai:DiVA.org:liu-140501DiVA, id: diva2:1140147
Anmärkning

Funding Agencies|European Union under a Marie Curie Initial Training Network USART-project [PITN-GA-2012-317132]; DOPPLER-CIP project (EU FP7 framework programme) [223615]

Tillgänglig från: 2017-09-11 Skapad: 2017-09-11 Senast uppdaterad: 2017-09-11

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Sök vidare i DiVA

Av författaren/redaktören
Engvall, Jan
Av organisationen
Avdelningen för kardiovaskulär medicinMedicinska fakultetenFysiologiska kliniken USCentrum för medicinsk bildvetenskap och visualisering, CMIV
I samma tidskrift
European Heart Journal Cardiovascular Imaging
Medicinsk laboratorie- och mätteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 577 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf