Digitala Vetenskapliga Arkivet

Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Gas chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry methods for the determination of environmental contaminants
Örebro universitet, Institutionen för naturvetenskap och teknik.ORCID-id: 0000-0002-8553-8824
2016 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

The recent developments and improvements of instrumental methods for the analyses of the environmental contaminants, especially the persistent organic pollutants (POPs), have made it possible to detect and quantify these at very low concentrations in environmental and biotic matrices.

The main objective of this thesis is to demonstrate the capability of the atmospheric pressure chemical ionization technique (APCI), using gas chromatography coupled to tandem mass spectrometry for the determination of a wide range of environmental contaminants, including the POPs regulated by Stockholm Convention, such as polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs), but also the derivates of PBDEs and novel brominated flame retardants (NBFRs).

The APCI was operated in charge transfer condition, preferably producing molecular ions. Multiple reaction monitoring (MRM) experiments were optimized by adjusting cone voltage, collision energy and dwell time. Optimization of source parameters, such as gas flows and temperatures was also performed. Low concentration standards were analyzed, achieving a visible chromatographic peak for 2 fg 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) demonstrating the excellent sensitivity of the system. Adequate linearity and repeatability were observed for all the studied compounds. The performance of APCI methods was validated against the conventional methods using gas chromatography coupled to high resolution mass spectrometry for chlorinated compounds in a wide range of matrices including environmental, air, human and food matrices.

The GC-APCI-MS/MS method was successfully applied to a set of 75 human serum samples to study the circulating levels of POPs in epidemiologic studies. Moreover the method was utilized to establish temporal trends of POPs in osprey eggs samples collected during the past five decades.

Ort, förlag, år, upplaga, sidor
Örebro: Örebro university , 2016. , s. 83
Serie
Örebro Studies in Chemistry, ISSN 1651-4270 ; 17
Nyckelord [en]
PCDD/Fs, PCBs, OCPs, PBDEs, NBFRs, APCI, MS/MS, HRMS, human serum, osprey egg
Nationell ämneskategori
Kemi Annan kemi
Forskningsämne
Kemi
Identifikatorer
URN: urn:nbn:se:oru:diva-51727OAI: oai:DiVA.org:oru-51727DiVA, id: diva2:954365
Disputation
2016-09-30, Örebro universitet, Musikhögskolan, Hörsalen, Fakultetsgatan 1, Örebro, 10:15 (Engelska)
Opponent
Handledare
Tillgänglig från: 2016-08-22 Skapad: 2016-08-22 Senast uppdaterad: 2021-02-15Bibliografiskt granskad
Delarbeten
1. Gas chromatography/atmospheric pressure chemical ionization/mass spectrometry for the analysis of organochlorine pesticides and polychlorinated biphenyls in human serum
Öppna denna publikation i ny flik eller fönster >>Gas chromatography/atmospheric pressure chemical ionization/mass spectrometry for the analysis of organochlorine pesticides and polychlorinated biphenyls in human serum
Visa övriga...
2016 (Engelska)Ingår i: Journal of Chromatography A, ISSN 0021-9673, E-ISSN 1873-3778, Vol. 1453, s. 88-98Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

A method using a novel atmospheric pressure chemical ionization source for coupling gas chromatography (GC/APCI) to triple quadrupole mass spectrometry (MS/MS) for the determination of organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) regulated by the Stockholm Convention is presented. One microliter injection of a six-point calibration curve of native PCBs and OCPs, ranging from 0.04 to 300 pg/μL, was performed. The relative standard deviation (RSD) of the relative response factors (RRFs) was less than 15% with a coefficient of determination (r2) >0.995. Meanwhile, two calibration solutions (CS), CS 2 (0.4 pg/μL) and CS 3 (4 pg/μL) were analyzed to study the repeatability calculated for both area and RRFs. The RSD for RRF ranged from 3.1 to 16% and 3.6 to 5.5% for CS 2 and CS 3, respectively. The limits of detection (LOD) determined by peak-to-peak signal-to-noise ratio (S/N) of 3 were compared between the GC/APCI/MS/MS and a GC coupled to high resolution mass spectrometry (GC/HRMS) system. GC/APCI/MS/MS resulted in lower LOD for most of the compounds, except for PCB#74, cis-chlordane and trans-chlordane. GC/APCI/MS/MS and GC/HRMS were also compared by performing analysis on 75 human serum samples together with eight QA/QC serum samples. The comparison between GC/APCI/MS/MS system and GC/HRMS system for 16 of the targeted compounds was carried out. No statistically significant difference was discovered. Due to increased sensitivity and user friendly operation under atmospheric pressure, GC/APCI/MS/MS is a powerful alternative technique that can easily meet the specification of GC/HRMS.

Ort, förlag, år, upplaga, sidor
Amsterdam, Netherlands: Elsevier, 2016
Nyckelord
PCBs, OCPs, atmospheric pressure chemical ionization (APCI), triple quadrupole mass spectrometry (MS/MS), high resolution mass spectrometry (GC/HRMS), human serum
Nationell ämneskategori
Kemi
Forskningsämne
Analytisk kemi; Miljökemi; Miljövetenskap
Identifikatorer
urn:nbn:se:oru:diva-50854 (URN)10.1016/j.chroma.2016.05.030 (DOI)000378182800010 ()27236485 (PubMedID)2-s2.0-84969722268 (Scopus ID)
Anmärkning

Funding Agency:

China Scholarship Council (CSC) under the Grant CSC 201206400003

Tillgänglig från: 2016-06-15 Skapad: 2016-06-14 Senast uppdaterad: 2018-09-12Bibliografiskt granskad
2. Atmospheric-Pressure Chemical Ionization Tandem Mass Spectrometry (APGC/MS/MS) an Alternative to High-Resolution Mass Spectrometry (HRGC/HRMS) for the Determination of Dioxins
Öppna denna publikation i ny flik eller fönster >>Atmospheric-Pressure Chemical Ionization Tandem Mass Spectrometry (APGC/MS/MS) an Alternative to High-Resolution Mass Spectrometry (HRGC/HRMS) for the Determination of Dioxins
Visa övriga...
2015 (Engelska)Ingår i: Analytical Chemistry, ISSN 0003-2700, E-ISSN 1520-6882, Vol. 87, nr 17, s. 9047-9053Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The use of a new atmospheric-pressure chemical ionization source for gas chromatography (APGC) coupled with a tandem quadrupole mass spectrometry (MS/MS) system, as an alternative to high-resolution mass spectrometry (HRMS), for the determination of PCDDs/PCDFs is described. The potential of using atmospheric-pressure chemical ionization (APCI) coupled to a tandem quadrupole analyzer has been validated for the identification and quantification of dioxins and furans in different complex matrices. The main advantage of using the APCI source is the soft ionization at atmospheric pressure, which results in very limited fragmentation. APCI mass spectra are dominated by the molecular ion cluster, in contrast with the high energy ionization process under electron ionization (El). The use of the molecular ion as the precursor ion in MS/MS enhances selectivity and, consequently, sensitivity by increasing the signal-to-noise ratios (S/N). For standard solutions of 2,3,7,8-TCDD, injections of 10 fg in the splitless mode on 30- or 60-m-length, 0.25 mm inner diameter (id), and 25 mu m film thickness low-polarity capillary columns (DB5MS type), signal-to-noise (S/N) ratios of >10:1 were routinely obtained. Linearity was achieved in the region (correlation coefficient of r(2) > 0.998) for calibration curves ranging from 100 fg/mu L, to 1000 pg/mu L. The results from a wide variety of complex samples, including certified and standard reference materials and samples from several QA/QC studies, which were previously analyzed by EI HRGC/HRMS, were compared with the results from the APGC/MS/MS system. Results between instruments showed good agreement both in individual congeners and toxic equivalence factors (TEQs). The data show that the use of APGC in combination with MS/MS for the analysis of dioxins has the same potential, in terms of sensitivity and selectivity, as the traditional HEMS instrumentation used for this analysis. However, the APCI/MS/MS system, as a benchtop system, is much easier to use.

Nationell ämneskategori
Analytisk kemi
Forskningsämne
Analytisk kemi
Identifikatorer
urn:nbn:se:oru:diva-46035 (URN)10.1021/acs.analchem.5b02264 (DOI)000360773100062 ()26267710 (PubMedID)2-s2.0-84940971553 (Scopus ID)
Anmärkning

Funding Agencies:

Generalitat Valenciana, as research group of excellence PROMETEO/2009/054

Serveis Centrals d'Instrumentacio Cientifica (SCIC) of the University Jaume I

China Scholarship Council 201206400003

Tillgänglig från: 2015-10-07 Skapad: 2015-10-07 Senast uppdaterad: 2018-07-02Bibliografiskt granskad
3. Analysis of Novel and Legacy Brominated Flame Retardants Including Their Derivates by Atmospheric Pressure Chemical Ionization Using Gas Chromatography Coupled to Triple Quadrupole Mass Spectrometry
Öppna denna publikation i ny flik eller fönster >>Analysis of Novel and Legacy Brominated Flame Retardants Including Their Derivates by Atmospheric Pressure Chemical Ionization Using Gas Chromatography Coupled to Triple Quadrupole Mass Spectrometry
(Engelska)Manuskript (preprint) (Övrigt vetenskapligt)
Nationell ämneskategori
Annan kemi
Forskningsämne
Kemi
Identifikatorer
urn:nbn:se:oru:diva-52072 (URN)
Tillgänglig från: 2016-09-09 Skapad: 2016-09-09 Senast uppdaterad: 2017-10-17Bibliografiskt granskad
4. Temporal Trends of Polychlorinated Biphenyls, Organochlorine Pesticides and Polybrominated Diphenyl Ethers in Osprey Eggs in Sweden over the Years 1966 – 2013
Öppna denna publikation i ny flik eller fönster >>Temporal Trends of Polychlorinated Biphenyls, Organochlorine Pesticides and Polybrominated Diphenyl Ethers in Osprey Eggs in Sweden over the Years 1966 – 2013
Visa övriga...
(Engelska)Manuskript (preprint) (Övrigt vetenskapligt)
Nationell ämneskategori
Annan kemi
Forskningsämne
Kemi
Identifikatorer
urn:nbn:se:oru:diva-52073 (URN)
Tillgänglig från: 2016-09-09 Skapad: 2016-09-09 Senast uppdaterad: 2024-01-16Bibliografiskt granskad

Open Access i DiVA

Cover(630 kB)115 nedladdningar
Filinformation
Filnamn COVER01.pdfFilstorlek 630 kBChecksumma SHA-512
5eb484a4ad7cd158a5c49e4ff116ccb9455d7388630280cac539fc4e5fabbd54103814369222625839b04954421023779ab8de6f4adeb6a86c94c82ca0e4e259
Typ coverMimetyp application/pdf
Introductory chapter(2335 kB)1235 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 2335 kBChecksumma SHA-512
f4df1e31814400364229b547654fc8991c5af3a503bd10a58d54f513f24c9ced7a52e540e929edb2a867761f7f0f26c6e313927401f612519cc635a8618e490b
Typ fulltextMimetyp application/pdf
Spikblad(135 kB)97 nedladdningar
Filinformation
Filnamn SPIKBLAD01.pdfFilstorlek 135 kBChecksumma SHA-512
64bb73fc195f1836e02a42a31c8767c30f10721e9a25112587a9e19a8c22bc2f4bfe67bef25c30e3b57e500410eef213f77958f69783ac92c938172f4d16d3f8
Typ spikbladMimetyp application/pdf

Sök vidare i DiVA

Av författaren/redaktören
Geng, Dawei
Av organisationen
Institutionen för naturvetenskap och teknik
KemiAnnan kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 1238 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 2042 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf