SMART VAR Generator to Manage Grid Voltage Stability issue of Low Frequency Switching Photovoltaic Inverters
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik.
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik.
2015 (engelsk)Independent thesis Advanced level (degree of Master (Two Years)), 30 poäng / 45 hpOppgave
Abstract [en]

Solar power, clean and abundant, is considered as a vital contributor in the effort of transforming world energy-mix to pollution-free and natural-regenerative sources.   The solar micro inverters have gained greater visibility during the past several years due to their higher efficiency, greater performances, longer life expectancy and many other benefits. But, integrating small scale [<15kW] renewable energy sources, especially the low frequency switching solar inverters to the low voltage distribution grid has its own challenges due to their inability to generate reactive power to maintain the static voltage stability of the grid.

Higher level of solar penetration has identified as a potential cause of low voltage grid instability due to lack of reactive power feeding and their tendency to keep on increasing the voltage higher than grid at the point of common connection [PCC] in order to inject the current to the grid. The studies and experience in voltage stability issues has resulted in introducing many new grid regulations to manage the grid voltage stability throughout the world.

The new regulation, VDE-AR-N-4105-2011 is a German grid regulation standard specifically focuses on the low voltage grid connected power generators. This regulation has addressed the reactive power requirements in terms of power factor and supply management to maintain the grid static voltage variation less than 3% at the PCC, when connecting any type of distributed power generators to the low voltage network.

This report discuss about the voltage stability issues related to low frequency switching inverters and present a solution to comply with low voltage grid regulation - VDE-AR-N-4105-2011; a SmartVar Generator concept, theory, design and functionality.

sted, utgiver, år, opplag, sider
2015. , 94 s.
Emneord [en]
grid tied solar inverters, reactive power, VDE-AR-N-4105, Grid voltage stability
HSV kategori
Identifikatorer
URN: urn:nbn:se:hig:diva-20595OAI: oai:DiVA.org:hig-20595DiVA: diva2:871496
Veileder
Examiner
Tilgjengelig fra: 2015-12-01 Laget: 2015-11-14 Sist oppdatert: 2015-12-01bibliografisk kontrollert

Open Access i DiVA

fulltext(2667 kB)264 nedlastinger
Filinformasjon
Fil FULLTEXT02.pdfFilstørrelse 2667 kBChecksum SHA-512
dd8a75a388e54f11151ba67787fbd212785ad6e94e1fcf404951cd9028c8009494dc863270d1d64b4c1f9265ad7724137994a2279a242f7ee7f1d07ca6606b19
Type fulltextMimetype application/pdf

Søk i DiVA

Av forfatter/redaktør
Perera, Sam Prasanna Kurukulasuriya
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 264 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 374 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf