Validation of phototesting for estimation of individual skin ultraviolet sensitivity based on a lengthwise attenuating ultraviolet B field.
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för samhällsmedicin. Linköpings universitet, Medicinska fakulteten.
Linköpings universitet, Institutionen för klinisk och experimentell medicin, Avdelningen för kliniska vetenskaper. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Hudkliniken i Östergötland.
Linköpings universitet, Institutionen för klinisk och experimentell medicin, Avdelningen för kliniska vetenskaper. Linköpings universitet, Medicinska fakulteten.
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för samhällsmedicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Närsjukvården i västra Östergötland, Forsknings- och utvecklingsenheten för Närsjukvården i Östergötland.
2015 (engelsk)Inngår i: Journal of Medical Engineering & Technology, ISSN 0309-1902, E-ISSN 1464-522X, Vol. 39, nr 2, s. 91-8Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Conventional skin UV-sensitivity phototesting is based on semi-quantitative assessment of minimal erythema dose (MED). This study demonstrates a method for quantitative MED determination, using a lengthwise attenuating UVB-field combined with tissue viability imaging (TiVi). The study aim was to investigate the agreement between MED acquired by traditional phototest and by the new method. Forty-seven voluntary subjects underwent phototesting with a traditional phototest and with the new technique. Test reading, carried out after 24 h, showed moderate agreement between the methods when assessed with TiVi (Kappa value=0.46) and visually (Kappa value=0.48). For the new method, no systematic differences were seen between outcomes assessed with TiVi or visually (95% CI for the mean difference=-1.6-2.0). In conclusion, the results give promising support for the concept of achieving a more precise MED estimation by combining continuous attenuating UV fields with new available bioengineering technology.

sted, utgiver, år, opplag, sider
2015. Vol. 39, nr 2, s. 91-8
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-115793DOI: 10.3109/03091902.2014.980523PubMedID: 25429800OAI: oai:DiVA.org:liu-115793DiVA, id: diva2:796675
Tilgjengelig fra: 2015-03-19 Laget: 2015-03-19 Sist oppdatert: 2019-02-11

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Søk i DiVA

Av forfatter/redaktør
Pettersson, ErikAnderson, ChrisHenricsson, JoachimFalk, Magnus
Av organisasjonen
I samme tidsskrift
Journal of Medical Engineering & Technology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 207 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf