Fuktutredning av massivträkonstruktion: Analys av vägg utan ångspärr
Högskolan Dalarna, Akademin Industri och samhälle, Byggteknik.
Högskolan Dalarna, Akademin Industri och samhälle, Byggteknik.
2014 (svensk)Independent thesis Basic level (degree of Bachelor), 10 poäng / 15 hpOppgaveAlternativ tittel
Moisture analysis of solid wood construction : Analysis of a wall without vapour barrier (engelsk)
Abstract [sv]

Rapporten ingår i ett FoU- projekt för Högskolan Dalarna, där målet är att ta fram en konstruktion utan ångspärr som ska klara dagens mått på lufttäthet och fuktkrav.

Syftet med denna rapport är att utreda hur fukt påverkar en byggnad medmassivträstomme och olika isoleringsmaterial utan ångspärr. Mineralull och träfiberisolering jämförs mot varandra för att se hur dessa påverkarfuktbelastningen i en väggkonstruktion. Testobjektet är lokaliserat i Dalarna, inget fukttillskott har funnits inomhus i byggnaden.

För att genomföra detta arbete har tre stycken olika metoder används. Ensimulering, verkliga uppmätta värden och en provtagning. Fuktsimuleringen genomfördes med hjälp av programmet WUFI, uppmätta värden i form av relativ fuktighet och temperatur har samlats in kontinuerligt under två års tid från väggkonstruktionen via mätsensorer. Provtagningen utfördes med ett fysiskt ingrepp på samma nivå i konstruktionen som mätsensorer var placerade.

Resultat presenteras i form av diagram och tabeller där det går att avläsa konstruktionens nulägesstatus i form av relativ fuktighet, temperatur, fuktkvot och mikrobiologisk påväxt. Isoleringsmaterialen påvisar en hög relativ fuktighet under vinterhalvåret längst ut i konstruktionen mot utomhusklimatet. Utomhusklimatet har visats spela stor roll i detta. Ingen direkt mikrobiologisk påväxt har påträffats trots en hög halt av fukt.

Resultaten visar att träfiberisoleringen har bättre förmåga att hantera fukt i jämförelse med mineralullen. En vidarestudie med fuktbelastning och 21 °C inomhus bör utföras. Men för att denna studie ska fungera rekommenderas en tvåstegstätad fasadlösning för att klara fuktbelastningen i väggkonstruktionen.

Abstract [en]

The report is part of a research and development project for Dalarna University,where the goal is to produce a design without a vapour barrier that will meettoday's measure of airtightness and moisture requirements.

The purpose of this report is to investigate how moisture affects a building withsolid wood and various insulation materials without vapour barrier. Mineral woolinsulation and wood fiber insulation will be compared against each other to seehow they affect the moisture load in a wall. The test object is located in Dalarna,no additional moisture load affect the indoor environment.

To carry out this work, three different methods are used. A moisture simulationwas performed using the program WUFI, measured values in terms of relativehumidity and temperature were collected over two years from the wall of thebuilding. A sampling was performed with a physical operation on the same levelin the wall where measurement sensors were placed.

Results are presented in form of graphs and tables where you can read thecurrent state of the construction in terms of relative humidity, temperature,moisture content and microbiological fouling. Insulation materials demonstrate ahigh relative humidity at outer layers of the construction during the wintermonths. The external environment has been shown to play a major part for theresults. No direct microbiological fouling has been detected despite a highcontent of moisture.

The result of wood fiber insulation demonstrates a better ability to handlemoisture. A further study with a moisture load and 21 degrees indoors should beperformed. But for this study to work it’s recommended to change the currentfacade solution to a two- step sealed facade solution to manage the moistureload in the wall.

sted, utgiver, år, opplag, sider
2014.
Emneord [en]
Moisture; Solid wood; Vapour barrier
Emneord [sv]
Fukt; Massivträ; Ångspärr
HSV kategori
Identifikatorer
URN: urn:nbn:se:du-14628OAI: oai:DiVA.org:du-14628DiVA: diva2:732034
Tilgjengelig fra: 2014-07-03 Laget: 2014-07-03 Sist oppdatert: 2015-04-14bibliografisk kontrollert

Open Access i DiVA

fulltext(6490 kB)369 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 6490 kBChecksum SHA-512
a5a33712354f50ca58db1eac4a8756c1c0b00467ade59f87ecc17159e7d17819e80f233dd04d44b1dd63216600e501a3815132b69a6bd0ba2c40c2433f930aa8
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 369 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 1586 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf