Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Transmission of bone conducted sound – Correlation between hearing perception and cochlear vibration
Sahlgrenska University Hospital, Göteborg University, Sweden.
Linköpings universitet, Institutionen för klinisk och experimentell medicin, Teknisk audiologi. Linköpings universitet, Hälsouniversitetet.ORCID-id: 0000-0003-3350-8997
Chalmers University of Technology, Göteborg, Sweden.
Chalmers University of Technology, Göteborg, Sweden.
Vise andre og tillknytning
2013 (engelsk)Inngår i: Hearing Research, ISSN 0378-5955, E-ISSN 1878-5891, Vol. 306, s. 11-20Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The vibration velocity of the lateral semicircular canal and the cochlear promontory was measured on 16 subjects with a unilateral middle ear common cavity, using a laser Doppler vibrometer, when the stimulation was by bone conduction (BC). Four stimulation positions were used: three ipsilateral positions and one contralateral position. Masked BC pure tone thresholds were measured with the stimulation at the same four positions. Valid vibration data were obtained at frequencies between 0.3 and 5.0 kHz. Large intersubject variation of the results was found with both methods. The difference in cochlear velocity with BC stimulation at the four positions varied as a function of frequency while the tone thresholds showed a tendency of lower thresholds with stimulation at positions close to the cochlea. The correlation between the vibration velocities of the two measuring sites of the otic capsule was high. Also, relative median data showed similar trends for both vibration and threshold measurements. However, due to the high variability for both vibration and perceptual data, low correlation between the two methods was found at the individual level. The results from this study indicated that human hearing perception from BC sound can be estimated from the measure of cochlear vibrations of the otic capsule. It also showed that vibration measurements of the cochlea in cadaver heads are similar to that measured in live humans.

sted, utgiver, år, opplag, sider
Elsevier, 2013. Vol. 306, s. 11-20
Emneord [en]
AC, BAHA, BC, BCI, Bone anchored hearing aid, CSF, HL, LDV, LSCC, MAPP, SD, SNR, TA, air conduction, bone conduction, bone conduction implant, cerebrospinal fluid, dB, decibels, hearing level, laser Doppler vibrometer, lateral semicircular canal, mastoid surface area that attaches to the petrous part of the temporal bone, signal to noise ratio, standard deviation, transcranial attenuation
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-98270DOI: 10.1016/j.heares.2013.08.015ISI: 000327578200002PubMedID: 24047594OAI: oai:DiVA.org:liu-98270DiVA, id: diva2:653885
Merknad

Funding agencies|Health & Medical Care Committee of the Regional Executive Board, Region Vastra Gotaland||Goteborg Medical Society||VINNOVA: Swedish Governmental Agency for Innovation Systems|2009-00190|

Tilgjengelig fra: 2013-10-07 Laget: 2013-10-07 Sist oppdatert: 2017-12-06bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Søk i DiVA

Av forfatter/redaktør
Stenfelt, Stefan
Av organisasjonen
I samme tidsskrift
Hearing Research

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 5603 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf