Amperometric Biosensor for estimation of Glucose-6-phosphate Using Prussian Blue Nanoparticles.
Department of Polymer Science and Technology, University of Calcutta, India.
Department of Polymer Science and Technology, University of Calcutta, India.
Linköpings universitet, Institutionen för fysik, kemi och biologi, Biosensorer och bioelektronik. Linköpings universitet, Tekniska högskolan. (Biosensors & Bioelectronics)ORCID-id: 0000-0002-1815-9699
2013 (engelsk)Inngår i: Analytical Biochemistry, ISSN 0003-2697, E-ISSN 1096-0309, Vol. 439, nr 2, s. 194-200Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Glucose-6-phosphateplays an important role in carbohydrate metabolism of all living organisms.Compared to the conventional analytical methods available for estimation of glucose-6-phosphate,the biosensors having relative simplicity, specificity, low-cost and fastresponse time are a promising alternative. We have reported a glucose-6-phosphatesensor based on screen-printed electrode utilizing Prussian blue nanoparticlesand enzymes, glucose-6-phosphate dehydrogenase and glutathione reductase. The Prussianblue nanoparticles acted as a mediator enhancing the rate of electrochemical responses.The Fourier transforminfrared spectroscopy and energy-dispersiveX-ray spectroscopy study confirmed the formation of Prussian blue, whereas, the atomic forced microscopy revealed that Prussian bluenanoparticles were about 25-30 nm in diameter. To obtainmaximum amperometric response, optimization studies were conducted for pH,enzyme and cofactor loading. The proposed glucose-6-phosphate biosensor showed goodstability, rapid response time and broad linear response in the range of 0.01-1.25mM and detection limit of 6.3 mM. The biosensor also worked well for serum samples and exhibitedexcellent anti-interference ability.

sted, utgiver, år, opplag, sider
2013. Vol. 439, nr 2, s. 194-200
Emneord [en]
Glucose-6-phosphate; Prussian blue nanoparticles; Screen-printed electrode; Amperometry
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-91855DOI: 10.1016/j.ab.2013.04.025ISI: 000322286900017OAI: oai:DiVA.org:liu-91855DiVA, id: diva2:619344
Tilgjengelig fra: 2013-05-03 Laget: 2013-05-03 Sist oppdatert: 2017-12-06

Open Access i DiVA

G6P(151 kB)1235 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 151 kBChecksum SHA-512
5ecbe6274e0ec1a17253be0f18ab6d978b9cec9fee9d1e30ae414ceac265612610b6ae1ad96f1e7a6895bbb607bbe1ca02894f7bd2297990eea4653f510907df
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekst

Søk i DiVA

Av forfatter/redaktør
Turner, Anthony
Av organisasjonen
I samme tidsskrift
Analytical Biochemistry

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 1235 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 384 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf