Digitala Vetenskapliga Arkivet

Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Intraosseous samples can be used for opioid measurements: An experimental study in the anaesthetized pig
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Anestesiologi och intensivvård.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Anestesiologi och intensivvård.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Anestesiologi och intensivvård.
National Veterinary Institute (SVA), Department of Chemistry, Environment and Feed Hygiene, Uppsala, Sweden.
Vise andre og tillknytning
2013 (engelsk)Inngår i: Scandinavian Journal of Clinical and Laboratory Investigation, ISSN 0036-5513, E-ISSN 1502-7686, Vol. 73, nr 2, s. 102-106Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Aim.

The intraosseous route provides access to the systemic circulation in an emergency situation when other forms of vascular access are unavailable and there is an urgent need for fluid or drug therapy. The intraosseous access has also been used for collecting samples for laboratory testing. A question that may arise in an unconscious or severely exhausted patient is whether this condition is caused by an unknown drug. We aimed to evaluate whether intraosseous samples could be used to measure opioids and to study the accuracy and precision of such measurements.

Methods.

Five healthy, anaesthetized pigs were treated with a continuous morphine infusion as part of the anaesthesia procedure. Samples for morphine testing were collected hourly for 6 h from two tibial intraosseous cannulae and a central venous catheter.

Results.

The differences in morphine concentrations between the two tibial intraosseous cannulae were less than 10% in 32/33 times. The values were also relatively stable over time.

Conclusion.

Our findings suggest that intraosseous samples can be used for the analysis of opioids if an IV route is not available.

sted, utgiver, år, opplag, sider
2013. Vol. 73, nr 2, s. 102-106
HSV kategori
Identifikatorer
URN: urn:nbn:se:uu:diva-185435DOI: 10.3109/00365513.2012.744088ISI: 000315896000002PubMedID: 23171472OAI: oai:DiVA.org:uu-185435DiVA, id: diva2:571755
Tilgjengelig fra: 2012-11-23 Laget: 2012-11-23 Sist oppdatert: 2018-01-12bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Søk i DiVA

Av forfatter/redaktør
Strandberg, GunnarEriksson, MatsLipcsey, MiklósLarsson, Anders
Av organisasjonen
I samme tidsskrift
Scandinavian Journal of Clinical and Laboratory Investigation

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 538 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf