Energieffektivisering av två flerbostadshus i Västerås, byggda 1963: Enerigbehovsberäkning med programmet VIP+
Mälardalens högskola, Akademin för hållbar samhälls- och teknikutveckling. Mälardalens högskola, Akademin för hållbar samhälls- och teknikutveckling.
Mälardalens högskola, Akademin för hållbar samhälls- och teknikutveckling.
2009 (svensk)Independent thesis Basic level (degree of Bachelor), 10 poäng / 15 hpOppgave
Abstract [en]

 

Abstract

The background for this study is that there were a great amount of buildings constructed in Sweden in the years 1965-1975 in a program designed to create one million apartments in a time-period of ten years. These buildings are now, somewhat forty years later in most cases in very poor condition and the need for renovation is great and urgent. This has become a growing problem and more and more voices are being heard pointing towards the vast and extremely expensive task of renovating these buildings. Lately, it has also been more and more important for buildings to be energy-efficient and sustainable environment friendly.

In recent years there has been an atempt to solve these problems by renovating such buildings but at the same time making them very energy-efficient. This is in some cases being done by isolating the shell of the building and changing the ventilation-system and so forth. Brogården in Alingsås is the first project to do so and it was finished in February 2009.

Our aim has been to simulate actions like the ones in Brogården on two houses from that period of time. By various calculations and conclusions we´ve shown what the result would be if we isolated the shell, replaced the windows with super-isolated windows and changed the ventilation-system.

To calculate the energy use we´ve been using a energy calculation program called VIP+ where we have built up the two houses artificially and then simulated the actions mentioned above to decide what the result would be. We have also translated the reduced energy use into a yearly cost to show what the total profit in money would be.

The result shows that if the decision would be to go through with this project on these two houses in Västerås they would gain a total of 53 % regarding the energy use in those two houses. This means that the total energy-use have been reduced from 128 kwh/m2 to 60 kwh/m2.

sted, utgiver, år, opplag, sider
2009. , s. 49
HSV kategori
Identifikatorer
URN: urn:nbn:se:mdh:diva-12216OAI: oai:DiVA.org:mdh-12216DiVA, id: diva2:415650
Uppsök
Technology
Veileder
Examiner
Tilgjengelig fra: 2011-05-09 Laget: 2011-05-09 Sist oppdatert: 2011-05-09bibliografisk kontrollert

Open Access i DiVA

fulltekst(2272 kB)793 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 2272 kBChecksum SHA-512
f08064aadaec68691dc49ea2e8548204ee87ebe7feb717e6f113043d62eae48fa89205ffb41129b6221a5e358e05ae4a88b4ffe0cfea6c71619c68498485786d
Type fulltextMimetype application/pdf

Søk i DiVA

Av forfatter/redaktør
Risborn, JonasOlofsson, Emanuel
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 793 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 343 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf