Digitala Vetenskapliga Arkivet

Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Mätosäkerhet hos DTM:er från två olika UAS/LiDAR-system: Jämförelse av LiDAR-sensorerna DJI Zenmuse L1 och Zenmuse L2
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för datavetenskap och samhällsbyggnad, Samhällsbyggnad.
2024 (svensk)Independent thesis Basic level (university diploma), 10 poäng / 15 hpOppgave
Abstract [sv]

Utvecklingen av luftburna laserskannersystem sker snabbt. De blir mer kompakta och får ett bättre slutresultat med lägre mätosäkerhet och högre punkttäthet. De nyare modellerna som tillverkas är som regel bättre än de äldre som de ersätter. Därför är det intressant att undersöka hur stor förbättringen är när det gäller mätosäkerhet och kvaliteten hos en nyare modell av luftburna laserskanningsystem i jämförelse med en äldre.

Inom ramen för studien har en jämförelse mellan DJI Zenmuse L2 och dess föregångare DJI Zenmuse L1 genomförts. Målet var att göra en ingående analys av enheterna med avseende på hur bra de presterar och hur användbara de är. Sensorernas prestanda undersöktes i fält genom att ett och samma område med varierande terräng och marktyp skannades med både Zenmuse L1 och Zenmuse L2. Insamlingen gjordes med sex flygningar där L1 och L2 var inställd på en, två och tre returer som sedan jämfördes mot varandra. Syftet var att avgöra vilken mätosäkerhet punktmolnen har. Kontrollprofiler och stödpunkter mättes med en totalstation enligt SIS-TS 21144:2016. DTM:er skapades från punktmolnen och utifrån jämförelser mellan DTM:erna och kontrollprofilerna beräknades standardavvikelse och medelavvikelse.

Utifrån analys av Zenmuse L1 och Zenmuse L2 gav det ett resultat som visar på att det inte har en sån stor skillnad mellan varandra i mätosäkerhet. I medelavvikelse var skillnad mellan L1 och L2 0,0113 m för retur 1, 0,0065 m för retur 2 och 0,0237 m för retur 3. I standardavvikelse blev skillnaden 0,0097 m för retur 1, 0,0052 m för retur 2 och 0,0016 m för retur 3. Medelavvikelsen blev bättre för L1 vid retur 2 och 3 men vid standardavvikelsen fick L2 ett bättre resultat än L1.

Abstract [en]

The development of airborne laser scanner systems is occurring rapidly. They are becoming more compact and achieving better results with lower measurement uncertainty and higher point density. The newer models that are produced are usually better than the older ones they replace. That is why it is interesting to investigate how significant the improvements are in terms of measurement uncertainty and quality when comparing a newer model of airborne laser scanning system in comparison to an older one.

Within the framework of the study, a comparison between DJI Zenmuse L2 and its predecessor DJI Zenmuse L1 has been carried out. The goal was to do an in-depth analysis of the devices in terms of their performance and usefulness. The performance of the sensors was investigated in the field by scanning the same area with varying terrain and soil types with both the Zenmuse L1 and Zenmuse L2. The data collection was done with six flights where L1 and L2 were set to one, two and three returns. These settings were then compared against each other. The purpose was to determine the measurement uncertainty of the point clouds and how well ground classification can be performed. Control profiles and check points were measured with a total station according to SIS-TS 21144:2016. DTMs were created from the point clouds and from comparisons between the DTMs the standard deviation and mean deviation of the control profiles were calculated.

Based on analysis of Zenmuse L1 and Zenmuse L2, the result shows that there is not such a significant difference between them in measurement uncertainty. In terms of mean deviation, difference between L1 and L2 was 0,0113 m for return 1, 0,0065 m for return 2 and 0,0237 m for return 3. In terms of standard deviation, the difference was 0,0097 m for return 1, 0,0052 m for return 2 and 0,0016 m for return 3. The mean deviation was better for L1 on returns 2 and 3 but on the standard deviation L2 achieved a better result than L1.

sted, utgiver, år, opplag, sider
2024. , s. v + 38 + bilagor
Emneord [sv]
Laserskanning, UAV, UAS-LiDAR, drönare, luftburen laserskanning, DTM
HSV kategori
Identifikatorer
URN: urn:nbn:se:hig:diva-45102OAI: oai:DiVA.org:hig-45102DiVA, id: diva2:1880634
Fag / kurs
Lantmäteriteknik
Utdanningsprogram
Surveying
Veileder
Examiner
Tilgjengelig fra: 2024-08-06 Laget: 2024-07-01 Sist oppdatert: 2025-02-07bibliografisk kontrollert

Open Access i DiVA

fulltext(4778 kB)40 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 4778 kBChecksum SHA-512
9ef76f245c34f83757822e51e4edb926e494781d392419fdb62f86528c935c61c30665ce4f75cb65da4b3a0047edccd98180cf607cb7b4889b01e53e2a3238fb
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 40 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 67 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf