The Effect of High Occupancy Density on IAQ, Moisture Conditions and Energy Use in Apartments
RISE - Research Institutes of Sweden (2017-2019), Samhällsbyggnad. Lund University, Sweden.ORCID-id: 0000-0002-3863-0740
Lund University, Sweden.
Lund University, Sweden.
2019 (engelsk)Inngår i: Energies, ISSN 1996-1073, E-ISSN 1996-1073, Vol. 12, nr 23, artikkel-id 4454Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Apartments built in Sweden during the record years 1961–1975 with the aim to remedy thehousing shortage and abolish poor standards, were designed for a normal-sized family of 2–4 persons.The mechanical ventilation system, if existing, was primarily designed to ensure an air exchange inthe apartment according to Swedish building regulations. During the last few years, the number ofovercrowded apartments has increased due to housing shortage in general but also due to migration.Another aspect is that the ventilation in many apartments built during the record years is alreadyinsucient at normal occupant load. The question is how doubling or tripling the number ofoccupants and thus, the moisture load will aect the risk of bad air quality and moisture damage.To find out, simulations were made to estimate whether it is possible to obtain sucient air qualityand low risk of moisture damage by only increasing the ventilation rates in existing systems orintroducing new ventilation systems with and without heat recovery and what the consequencewould be in terms of the additional energy demand. Measurements from earlier studies of CO2 andmoisture supply in Swedish apartment buildings were used as input data.

sted, utgiver, år, opplag, sider
2019. Vol. 12, nr 23, artikkel-id 4454
Emneord [en]
occupancy density; moisture conditions; energy use; indoor air quality; ventilation rate
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-40853DOI: 10.3390/en12234454Scopus ID: 2-s2.0-85076137008OAI: oai:DiVA.org:ri-40853DiVA, id: diva2:1372360
Merknad

(This article belongs to the Special Issue Energy and Technical Building Systems - Scientific and Technological Advances)

Tilgjengelig fra: 2019-11-22 Laget: 2019-11-22 Sist oppdatert: 2020-02-07bibliografisk kontrollert

Open Access i DiVA

fulltext(2299 kB)30 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 2299 kBChecksum SHA-512
6514a250519b681fa74af3336276ebb9ea4f8d1f504f9d3f1d102e93ff7a993188e3195fb48e464536bbb413259bb8bc101b00ee570c73e0b9ea4fe282203bb8
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstScopus

Søk i DiVA

Av forfatter/redaktør
Mjörnell, Kristina
Av organisasjonen
I samme tidsskrift
Energies

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 30 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 22 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf