Vibrations in residential timber floors: A comparison between the current and the revised Eurocode 5
Linnéuniversitetet, Fakulteten för teknik (FTK), Institutionen för byggteknik (BY).
Linnéuniversitetet, Fakulteten för teknik (FTK), Institutionen för byggteknik (BY).
2019 (engelsk)Independent thesis Advanced level (degree of Master (One Year)), 10 poäng / 15 hpOppgave
Abstract [en]

The European standard Eurocode 5, a design method for timber structures,is currently under revision. In this study the draft for a reviseddesign method for vibrations in timber floors was compared to the currentmethod. The hypothesis of the thesis was that the revised designmethod might force some changes to the present construction practiceand that these changes may carry with them increased costs for the industry.Six common floor structures used in Sweden today were identifiedand for these floors design calculations were made according to the currentand the revised design method. It was checked whether the floorspassed the criteria in the two design methods and a comparison was madefor the only criterion which could be compared between the methods, thepoint load deflection. Floor structures could pass or fail the current designmethod based on two criteria, the point load deflection and the unitimpulse velocity response. All floors passed the current design methodexcept one which had a fundamental frequency below 8 Hz, because ofthe low frequency the current design method was not applicable to thefloor structure. In the revised design method the final result is a responsefactor and based on the response factor floors are given floor performancelevels. The seven step scale for the floor performance level go from I toVII where I is excellent and VII is unacceptable. All floor structures excepttwo achieved an acceptable floor performance level according to therevised design method. The two floors which failed were floors commonlyused in single family houses, they failed for a span length commonly usedtoday. A limited parametric study was performed where it was found thatthe modal mass used had a larger impact on the floor performance levelthan the mass per square meter included. For floors with a fundamentalfrequency above 8 Hz, including a higher mass per square meter resultedin a lower, i.e. better, response factor in all cases except one. For floorswith a fundamental frequency between 4.5 and 8 Hz, a higher mass resultedin a higher, i.e. worse, response factor. The study found that notall floor structures used in Sweden today are acceptable according to therevised design method therefore changes may have to be implemented andthese changes could result in an increased cost.

sted, utgiver, år, opplag, sider
2019. , s. 100
Emneord [en]
Vibration; Eurocode 5; Floor design method; Timber floor construction; Sensitivity study; Parametric study
HSV kategori
Identifikatorer
URN: urn:nbn:se:lnu:diva-89293OAI: oai:DiVA.org:lnu-89293DiVA, id: diva2:1354527
Eksternt samarbeid
RISE, Research Institutes of Sweden
Fag / kurs
Byggteknik
Utdanningsprogram
Structural Engineering, Master Programme, 60 credits
Presentation
2019-05-29, 09:00 (engelsk)
Veileder
Examiner
Tilgjengelig fra: 2019-09-25 Laget: 2019-09-25 Sist oppdatert: 2019-09-25bibliografisk kontrollert

Open Access i DiVA

fulltext(7175 kB)5459 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 7175 kBChecksum SHA-512
bdaf64255be855c2087ecad761fe056102f2a14cf9c87ea07e6d8582f338ef6dc26f66876ec7e0569ea812234de3dca1bb944d457ac761bcc018bbc2cbde6080
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 5472 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 950 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf