Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Transmission of bone-conducted sound in the human skull measured by cochlear vibrations
Linköpings universitet, Institutionen för klinisk och experimentell medicin. Linköpings universitet, Hälsouniversitetet.
Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för klinisk och experimentell medicin, Teknisk audiologi.ORCID-id: 0000-0003-3350-8997
University of Gothenburg.
University of Gothenburg.
2008 (engelsk)Inngår i: International Journal of Audiology, ISSN 1499-2027, E-ISSN 1708-8186, Vol. 47, nr 12, s. 761-769Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

One limitation with the Bone Anchored Hearing Aid (Baha) is too poor amplification for patients with moderate to severe sensorineural hearing losses. Therefore, we investigated if bone conducted (BC) sound transmission improves when the stimulation approaches the cochlea. Also the influence from the squamosal suture on BC sound transmission was investigated. Both sides of the heads on seven human cadavers were used and vibrational stimulation was applied at eight positions on each side with a frequency range of 0.1-10 kHz. A laser Doppler vibrometer was used to measure the resulting velocity of the cochlear promontory. It was found that the velocity of the promontory increases as the stimulation position approaches the cochlea; this was especially apparent at distances within 2.5 cm from the ear canal opening and when the stimulation position was in the opened mastoid. At frequencies above 500 Hz there was on average 10 to 20 dB greater vibrational response at the cochlea when the stimulation was close to the cochlea compared with the normal Baha position. Moreover, even if there were general indications of attenuation of BC sound when passing the squamosal suture, an effect from the suture could not be conclusively determined.

sted, utgiver, år, opplag, sider
2008. Vol. 47, nr 12, s. 761-769
Emneord [en]
Bone conduction, Distance from the cochlea, Squamosal suture, Laser Doppler vibrometer, Implantable bone conduction hearing aid
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-16257DOI: 10.1080/14992020802311216OAI: oai:DiVA.org:liu-16257DiVA, id: diva2:133537
Tilgjengelig fra: 2009-01-12 Laget: 2009-01-09 Sist oppdatert: 2017-12-14

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Søk i DiVA

Av forfatter/redaktør
Stenfelt, Stefan
Av organisasjonen
I samme tidsskrift
International Journal of Audiology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 314 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf