Impact of a zoledronate coating on early post-surgical implant stability and marginal bone resorption in the maxilla-A split-mouth randomized clinical trial.
Linköpings universitet, Institutionen för klinisk och experimentell medicin, Avdelningen för Kirurgi, Ortopedi och Onkologi. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Sinnescentrum, Käkkliniken US.
Region Östergötland, Sinnescentrum, Käkkliniken US.
Linköpings universitet, Institutionen för klinisk och experimentell medicin, Avdelningen för Kirurgi, Ortopedi och Onkologi. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Centrum för kirurgi, ortopedi och cancervård, Ortopedkliniken i Linköping.
2019 (engelsk)Inngår i: Clinical Oral Implants Research, ISSN 0905-7161, E-ISSN 1600-0501, Vol. 30, nr 1, s. 49-58Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

OBJECTIVES: The objective of this clinical study was to evaluate the effect of a bisphosphonate coating on a titanium implant on the implant stability quotient (ISQ) and the radiographic marginal bone levels at implants during early healing (2-8 weeks).

MATERIALS AND METHODS: In a randomized double-blind trial with internal controls, 16 patients received a dental implant coated with zoledronate and one uncoated implant as a control. The coated and uncoated implants which were visually indistinguishable were bone level titanium implants with a moderately rough surface and a microthreaded neck. ISQ values were obtained at insertion and at 2, 4, 6, and 8 weeks. Radiographs were obtained at insertion and at 8 weeks. The primary outcome was the difference in ISQ values between the coated implants and the control implants at 4 and 6 weeks, corrected for insertion values. The secondary outcome was loss of marginal bone level from insertion to 8 weeks.

RESULTS: Implant stability quotient values remained largely constant over the 8 weeks, and there was no significant difference between coated and uncoated implants at any time point. There was 0.12 (SD 0.10) mm marginal bone loss at the control implants and 0.04 (SD 0.08) mm at the coated implants. The difference was 0.17 mm; SD 0.14; p < 0.006). On blind qualitative scoring, 13 of the 15 control implants and two of 15 coated implants showed small marginal bone defects (p = 0.003).

CONCLUSIONS: There were no statistically significant differences observed in ISQ values between the coated and uncoated implants during the early healing. There was less marginal bone loss at the coated implants.

sted, utgiver, år, opplag, sider
John Wiley & Sons, 2019. Vol. 30, nr 1, s. 49-58
Emneord [en]
dental implant, fibrinogen, maxilla, radiography
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-153634DOI: 10.1111/clr.13391ISI: 000456748800004PubMedID: 30565741OAI: oai:DiVA.org:liu-153634DiVA, id: diva2:1275407
Tilgjengelig fra: 2019-01-06 Laget: 2019-01-06 Sist oppdatert: 2019-02-27

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Søk i DiVA

Av forfatter/redaktør
Abtahi, JahanHenefalk, GustavAspenberg, Per
Av organisasjonen
I samme tidsskrift
Clinical Oral Implants Research

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 581 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf