Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
MULTI-CENTER QUANTITATIVE MEASUREMENT OF T1 ANDT2 RELAXATION TIMES IN THE RAT BRAIN
KTH, Skolan för kemi, bioteknologi och hälsa (CBH).
2018 (engelsk)Independent thesis Advanced level (degree of Master (Two Years)), 20 poäng / 30 hpOppgaveAlternativ tittel
Multicenter-kvantitativa T1 och T2 relaxationstidsmätningar i smådjurshjärna (svensk)
Abstract [en]

This project revolves around the measurement of T1 and T2 relaxation times in the ratbrain, in a multi-center way. That is to say, elaborate an efficient protocol to calculate highresolution 3D map of the brain. This protocol should be applied in different centers andreturn similar results. Finally, procedures should be defined to ease the collaborationbetween the different centers. The first step consisted in in vitro experiments, in whichdifferent sequences were tested. It resulted that the MDEFT sequence with inversionpreparation (MPRAGE) gives the best results in the shortest time for T1. For T2, theMSME sequence was chosen. The next step moved on in vivo experiments on three rats inorder to get used to manipulating living animals and make new adjustments. As thephysiology is not the same on in vitro and in vivo experiments, some parameters had to beslightly adapted. Once the final 2h-protocol was established, it was tested on a populationof ten rats. Experiments were made at the GIN and CRMBM. Different fitting pipelineswere tried (GIN, CRMBM, MIRCEN). The brain was segmented into different regions. Itresulted that the GIN and CRMBM pipelines return the same T1 values using the differentdatasets. The MIRCEN pipeline under-estimates by 200 ms. The three pipelines return similar T2 values. The GIN and CRMBM datasets provide comparable T1 values, but theGIN center presents slightly higher T2 values. Regarding the multi-center collaboration,the different pipelines were ported to the VIP platform so that the scientific community caneasily reuse them.

sted, utgiver, år, opplag, sider
2018. , s. 90
Serie
TRITA-CBH-GRU ; 2018:73
Emneord [en]
MRI; Relaxation Times; T1; T2; Rat; Brain; Quantitative; Multi-center
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-232040OAI: oai:DiVA.org:kth-232040DiVA, id: diva2:1231794
Eksternt samarbeid
Grenoble Institute of Neurosciences - 31 Chemin Fortuné Ferrini, 38700 La Tronche, France
Fag / kurs
Medical Engineering
Utdanningsprogram
Master of Science - Medical Engineering
Veileder
Examiner
Tilgjengelig fra: 2018-07-19 Laget: 2018-07-09 Sist oppdatert: 2018-07-19bibliografisk kontrollert

Open Access i DiVA

DERUELLE_STUDENT_THESIS(4070 kB)19 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 4070 kBChecksum SHA-512
42370bd181dba600026a8d84ff7917926f3bea0ee75cceb4aa11b928de664d889091e6d65d207dd1ac587b838d52c0b60dd01cde79bad03e24180c59bb30e451
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 19 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 65 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf