Estimating patient peak skin dose with fluoroscopic procedures
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för fysik. Man.
2018 (engelsk)Independent thesis Advanced level (professional degree), 20 poäng / 30 hpOppgave
Abstract [en]

During image guided interventional radiology (IR) procedures, acute X-ray induced skin injuries may occur due to high absorbed patient skin dose. These procedures are highly dependent on X-ray imaging both for guiding fluoroscopy and high quality diagnostic image acquisitions. A dose metric that quantifies the peak absorbed skin dose (PSD) is therefore of great importance, both in terms of patient specific follow-up and for imaging protocol optimization. Presently, the cumulative interventional reference point (IRP) air Kerma is the most common skin dose estimation metric in use. This metric lacks several important dose contributions, such as pre-patient attenuation, air-to-skin medium correction, scattering from the patient and the support table, and fluence correction for actual source-to-skin distance.

In this manuscript, we present a novel methodology for estimating the maximum absorbed skin dose by using dose related X-ray equipment parameters, such as peak tube voltage, support table position and IRP air Kerma obtained from radiation dose structured reports (RDSR) generated by modern IR equipment. In particular, Siemens Artis Zee (Siemens Healthineers, Erlangen, Germany) and Philips Allura Clarity (Philips, Amsterdam, Netherlands). The calculation process was automated by the development of a series of programming scripts in the PythonTM programming language v3.6 (Python Software Foundation), together with a database storing correction factors and machine specific parameters such as half-value layer (HVL).

The proposed calculation model enables the implementation of a dose metric which corresponds better to absorbed skin dose than IRP air Kerma in clinical settings. However, extensive future work is required for a complete PSD implementation, in particular, the development of a skin dose map in which the spatial location of each irradiation event is tracked.

sted, utgiver, år, opplag, sider
2018. , s. 50
Emneord [en]
skin dose, radiation dose structured reports, interventional radiology, radiation dosimetry
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-149053OAI: oai:DiVA.org:umu-149053DiVA, id: diva2:1218386
Eksternt samarbeid
centrum för medicinsk teknik och strålningsfysik, Norrlands universitetssjukhus
Fag / kurs
Examensarbete i teknisk fysik
Utdanningsprogram
Master of Science Programme in Engineering Physics
Presentation
2018-06-11, Universitetsklubben, Universums gränd 4907 36, Umeå, 10:00 (svensk)
Veileder
Examiner
Tilgjengelig fra: 2018-08-13 Laget: 2018-06-14 Sist oppdatert: 2018-08-13bibliografisk kontrollert

Open Access i DiVA

fulltext(2619 kB)115 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 2619 kBChecksum SHA-512
7d762d57f2f1fff674c14d88bfbc003eb7a51476cf7a39232f94c2e8bef35183d9a0155d42c92195253fd5a4d6ad023005acb19ff87a31b9bdb54177903eed35
Type fulltextMimetype application/pdf

Søk i DiVA

Av forfatter/redaktør
Hellström, Max
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 115 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 322 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf